Temporary Operation; Air Purifying Control - Toshiba RAS-18, 22SKV-E Service Manual

Hide thumbs Also See for RAS-18, 22SKV-E:
Table of Contents

Advertisement

Item
10. Temporary
Pushing [RESET] button starts the temporary
operation
operation of [AUTO] operation. When keeping
[RESET] button pushed for 10 seconds or more, the
temporary [COOL] operation is performed.
Filter lamp ON
NO
Did you push [RESET] button
for 3 seconds or more?
YES
Did you push [RESET] button
for 10 seconds or more?
NO
Switch to [AUTO RESTART] control.
11. Air purifying
This function generates nagative ion while cleaning the air in the room.
control
If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation,
RAS-18SKVR-E,
and if it is received while the air conditioner operates, the air conditioner and the air purifier start
RAS-18SKVR-A,
operation.
RAS-22SKVR-E,
The air ion generator operates linked with the air purifying operation.
RAS-22SKVR-A
only
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Air purifying operation
AC + Air purifying operation
Sending air purifier-ON
1
Air conditioner stops
Operation lamp ON
*1
Memory position
of louver/COOL
*2
Fan ON
Air purifier ON
Air purifying operation
Operation flow and applicable data, etc.
YES
Push RESET button.
NO
Temporary [AUTO] operation
YES
Temporary [COOL] Operation
Operation button
PURE button
Air purifier
Stop (All)
AC + Air purifier
AC operation
Louver*1
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
Follows to AC operation
,
2
1
2
Air conditioner operates
Start of air purifier-ON
Air conditioner +
air purifier operate
1) When pushing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pushed for
3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pushed for
10 seconds or more, "Pi" sound is heard
and the temporary [COOL] operation
starts.
4) If the filter lamp goes on, push [RESET]
button to go off the filter lamp, and then
push [RESET] button again.
5) To stop the temporary operation, push the
button again.
* When the previous operation was the
operation of air conditioner + air purifier,
an operation of air conditioner + air purifier
starts by pushing AC button on the remote
Air conditioner
controller.
AC operation*
(Operation of air conditioner + air purifier is
AC + Air purifier
stored in memory.)
All stop
*1 Swing is available
All stop
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) → (L) → (L–) → (SL).
Fan speed *2
Sending air purifier-OFF
3
Air purifier operates
Operation lamp OFF
Fan stop
Air purifier-OFF
Louver close
All stop
– 43 –
FILE NO. SVM-10050
Description
,
3
4
4
Air conditioner +
Air purifier operate
Filter-OFF
Air conditioner operates

Hide quick links: