Configuring Communication
When using multiple panels within a NetLinx System, remember to assign unique
Device Number values to each panel so that all assigned panels appear in the
System listing for the target Master.
6.
Press Done to close the keypad, assign the number, and return to the Protected Setup page.
FIG. 50
Protected Setup page
7.
Press the on-screen Reboot button to restart the panel and incorporate any changes.
Before continuing, open NetLinx Studio 2.4. This program assists in developing a
System Number, Master IP/URL, and Master Port number. Refer to your NetLinx
Master's instruction manuals for more information.
8.
Obtain the System Number and Master IP Address from NetLinx Studio. This information must be
specific for the system used with the configured Modero panel.
9.
Press the grey Front Setup Access button for 3 seconds to open the Setup page.
10.
Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup
page.
11.
Press the System Connection button (located on the Protected Setup page) to open the System
Connection page (FIG. 51) and begin configuring the communication settings on the panel to match those
of the target Master.
connection
information
MAC Address
from panel is
factory set to a
unique address
FIG. 51
System Connection page
50
Modero
NetLinx Master's
connection
information
CV17 17" Modero Coor Video Touch Panels

Advertisement

Table of Contents