AMX NXT-CV17 Operation/Reference Manual page 82

17" modero touch panel
Hide thumbs Also See for NXT-CV17:
Table of Contents

Advertisement

Upgrading Modero Firmware
FIG. 68
Send to NetLinx Device dialog (showing Modero firmware update via IP)
8.
Select the panel's KIT file from the Files section (FIG. 68).
9.
Enter the Device value associated with the panel and the System number associated with the Master
(listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.
10.
Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update
process is complete. The reboot of the panel can take up 30 seconds after the firmware process has
finished.
11.
Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog
(FIG. 68).
12.
Click Close (after the panel reboots) to return to the main program.
13.
Right-click the associated System number and select Refresh System. This causes a refresh of all project
systems, establishes a new connection to the Master, and populates the System list with devices on your
particular system.
72
Selected Firmware file
Description field for selected KIT file
Firmware download
status
Device value and System number
must match the values
listed in the Workspace window