7.12 Check pump operation/pump
release
The pump electronic control circuit automati-
cally releases the pump.
Connect the boiler to the mains .
Make sure that the ambient thermostat is in
the "heat demand" position.
Check that the boiler with the gas cock shut-
off goes into ignition lockout (Er01) and, in the
meantime, check the pump release.
The pump release can be verified by checking
that the pump motor vibrates.
If the pump motor does not vibrate, release
the boiler from its lockout due to gas failure
by pressing the reset button on the control
panel and repeat the sequence a maximum of
10 times.
If the pump does not release, contact technical
support.
Once the pump has been released, open the
gas cock and check that the boiler operates
correctly both in domestic hot water and heat-
ing modes.
7.13
Checking the condensate
drain pipe
Check the soundness and integrity of the
condensate drain pipe.
Verify the cleanness and correct filling of the
condensate traps.

7.14 Instructing the user

Hand over this combined User & Installation
manual and the Service manual to the end
user and explain how to use the unit in both
c.h. and d.h.w. modes.
Take the User step by step through the light-
ing instructions.
Show the User how to switch off the appli-
ance quickly and indicate the position of the
electric supply isolator.
Explain the proper use and adjustment of all
system controls; this will ensure the great-
- 56 -
COMMISSIONING
est possible fuel economy.
Explain the function and use of the function
selector.
Explain and demonstrate the function of
time and temperature controls (if fitted).
Explain how to turn off the appliance for
both short and long periods and advise on
the precautions necessary to prevent dam-
age should the appliance be inoperative
when freezing conditions may occur.
Fill in the details required on the Boiler
Guarantee Certificate and hand to the User
advising them to return the correct section
for boiler Guarantee registration.
Finally, advise the User that, for continued
safe and efficient operation, the appliance
must be serviced by a competent person at
least once a year.