Electrical Connections - Biasi RIVA PLUS HE 24C ERP User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for RIVA PLUS HE 24C ERP:
Table of Contents

Advertisement

max =8,5 m
ø 125
Fig. 6.10
Pluming kit (Fig. 6.11) (Fig. 6.11)
Co-axial ø 60/100 mm + vertical part ø 60
mm (flue outlet).
This kit allows the combustion air to be
sucked up and expel the burnt gases directly
to the outside through a telescopic co- axial
flue (450-950 mm).
Type C52
90° =--- 0,85 m
ø 60 mm
45° =--- 0,65 m
Fig. 6.11
In the last section, the fumes are expelled
through a vertical section.
Extensions and elbows can be added to ex-
tend the kit's length.
The chart of Fig. 6.12 gives the allowable
- 48 -
INSTALLATION
Type C32
90° =--- 1 m
45° =--- 0,5 m
90° =--- 1 m
ø 60/100 mm
45° =--- 0,5 m
dimensions of the ducts "a" and "b" of Fig.
6.11.
"a" vertical length (m)
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
Allowed values
0.6
0.4
0.2
0.0
0.4
0.6
0.8
1.0
Fig. 6.12
Each additional elbow reduces the overall
acceptable length of the flue system as fol-
lows:
45° (60/100 mm) reduce length by 0,5 m.
90° (60/100 mm) reduce length by 1 m.
45° (60 mm) reduce length by 0,65 m.
90° (60 mm) reduce length by 0,85 m.
6.9

Electrical connections

• Remove the front panel of the case (see
the section 9.2 in this manual).
• Remove the screws K (Fig. 6.13).
• Loosen the screws L.
1.2
1.4
1.6
1.8
"b" horizontal length (m)