7.10 Checking the flue system

The flue system should be visually checked
for soundness. Check all clamps, gaskets and
fixing are secure and tight.
Ensure that the flue terminal is sited correctly
in accordance with the flue fitting instructions
and Fig. 5.1 on page 26 of this manual.
To carry out a combustion check refer to the
instructions given in the section "Combustion
analysis check" to page 51.
Reference figures are given in the "Technical
Data" section page. 18 of this manual (Flue
gas figures).
7.11 Check pump operation/pump
release
The pump electronic control circuit automati-
cally releases the pump.
Connect the boiler to the mains .
Make sure that the ambient thermostat is in the
"heat demand" position.
Check that the boiler with the gas cock shut-
off goes into ignition lockout (Er01) and, in the
meantime, check the pump release.
The pump release can be verified by checking
that the pump motor vibrates.
If the pump motor does not vibrate, release the
boiler from its lockout due to gas failure by press-
ing the reset button on the control panel and re-
peat the sequence a maximum of 10 times.
If the pump does not release, contact technical
support.
Once the pump has been released, open the gas
cock and check that the boiler operates correctly
both in domestic hot water and heating modes.
7.12 Checking the condensate drain
pipe
Check the soundness and integrity of the con-
densate drain pipe.
COMMISSIONING
Verify the cleanness and correct filling of the
condensate traps.

7.13 Instructing the user

Hand over this combined User & Installation
manual and the Service manual to the end
user and explain how to use the unit.
Take the User step by step through the lighting
instructions.
Show the User how to switch off the appliance
quickly and indicate the position of the electric
supply isolator.
Explain the proper use and adjustment of all
system controls; this will ensure the greatest
possible fuel economy.
Explain the function and use of the function
selector.
Explain and demonstrate the function of time
and temperature controls (if fitted).
Explain how to turn off the appliance for both
short and long periods and advise on the pre-
cautions necessary to prevent damage should
the appliance be inoperative when freezing
conditions may occur.
Fill in the details required on the Boiler Guar-
antee Certificate and hand to the User advis-
ing them to return the correct section for boiler
Guarantee registration.
Finally, advise the User that, for continued
safe and efficient operation, the appliance
must be serviced by a competent person at
least once a year.