Installing The Boiler - Biasi RIVA PLUS HE 24C ERP User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for RIVA PLUS HE 24C ERP:
Table of Contents

Advertisement

Do not forget to remove the transit caps and plugs from the boiler connections these are
fitted to every boiler.
Keep the boiler clear of dust during installation and in particular do not allow any dust or
debris to enter the top of the boiler where the flue connection is made. It is recommended
that you put a dust sheet over the top of the boiler until you are ready to make the flue
connection.
Remember to release the auto air purge before filling the boiler. See the instructions to
identify the location of this device.
This boiler allows to control the flow temperature of the central heating system at very
low levels. In case of underfloor heating system a temperature limiting device (e.g. a
safety thermostat) is recommended to stop the boiler in case that the water temperature
exceeds the design temperature.
You are strongly advised to the British Standard BS 7593-2006 Code of practice,flush out
the system both cold and hot in order to remove system and installation debris.
It is also sensible to initially fire and commission the boiler before connecting any external
controls such as a room thermostat. By following this procedure if you have a subsequent
problem this method if you have a subsequent problem following the addition of an exter-
nal control you can eliminate the boiler from your fault analysis.
If the boiler is fitted with a digital programmer, when setting the times for automatic opera-
tion, remember that for every "ON" time there must be an "OFF" time to follow and that
on every occasion you enter a time you must also indicate which days that you want the
boiler to follow the timed settings.
Some products incorporate an anti cycling time delay. It is normal when first switching the
boiler on for the boiler to operate on heating for a few seconds then switch off. After 3 - 4
minutes has elapsed the boiler will then re ignite and operate perfectly normally. The igni-
tion delay cycle does not prevent normal operation of the boiler to provide d.h.w.
If you are in any doubts as to the installation or operation of the boiler please read the
instruction manuals thoroughly and then if necessary contact Biasi UK for advice and as-
sistance.
Guarantee conditions. The guarantee registration form must be returned within 30 of
purchase, failure to comply will invalidate the guarantee.
Please remember that if you are in any doubt about the installation of this product you can
contact our Technical Helpline on tel. 01922 714 600.
Abbreviations used in the manual:
C.h. = Central heating
D.h.w. = Domestic hot water
D.c.w. = Domestic cold wate