Panasonic DP-C405 Service Handbook page 412

Digital color imaging systems
Hide thumbs Also See for DP-C405:
Table of Contents

Advertisement

No.
Item
505 Edge PWM Adj. Y 1200dpi
506 Edge PWM Adj. M 1200dpi
507 Edge PWM Adj. C 1200dpi
508 Edge PWM Adj. BK1200dpi
509 Not Used
510 Dot PWM Adj. Y 1200dpi
511 Dot PWM Adj. M 1200dpi
512 Dot PWM Adj. C 1200dpi
513 Dot PWM Adj. BK1200dpi
514 Not Used
515 STR Cleaning Adj. +
516 STR Cleaning Adj. -
517-
Not Used
519
520 TDC Gain Adj. Y
521 TDC Gain Adj. M
522 TDC Gain Adj. C
523 TDC Gain Adj. BK
524 TDC Gain Adj. B/W
525 TDC Image Limit Adj. Y
(DP-C322 Series Only)
526 TDC Image Limit Adj. M
(DP-C322 Series Only)
527 TDC Image Limit Adj. C
(DP-C322 Series Only)
528 TDC Image Limit Adj. BK
(DP-C322 Series Only)
529 Not Used
Ver. 1.1
F6 Mode
Remarks
(Factory use only)
(Factory use only)
Cleaning voltage plus value for STR adjustment.
(Factory use only)
Cleaning voltage minus value for STR adjustment.
(Factory use only)
(Factory use only)
412
DP-C405/C305/C265
Setting Range
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-127 ~ +127
0.39 %/step
-32 ~ +9
28.04 V/step
-32 ~ +127
28.04 V/step
-127 ~ +127
0.039 V/step
-127 ~ +127
0.039 V/step
-127 ~ +127
0.039 V/step
-127 ~ +127
0.039 V/step
-127 ~ +127
0.039 V/step
0 ~ +24
0 ~ +24
0 ~ +24
0 ~ +24
FEB 2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-c305Dp-c265

Table of Contents