E. Installing the Optional Heat-Zone
Kit
• Locate the Heat-Zone
®
the appliance. See Figure 5.6. Remove the knockouts
from the appliance with a tin snips.
• Center the duct collar around the exposed hole and
attach it to the appliance with 3 screws. Note: Do this
BEFORE fi nal positioning of the appliance.
• Determine the location for the air register/fan housing
assembly.
Reference the Heat-Zone
remaining installation steps.
HEAT ZONE
LOCATION
®
LEFT AND RIGHT SIDES
Figure 5.6 Heat Zone Cover Plate
28
®
ports on the left and right sides of
Gas Kit instructions for the
®
Heat & Glo • LUX36, LUX42 Installation Manual
Gas
• 2287-980 Rev. L • 4/16
• 2287-980 Rev. L