Heat & Glo LUX42 Installation Manual
Hide thumbs Also See for LUX42:
Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
LUX36
LUX42
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation Manual
Installation and Appliance Setup
Heat & Glo • LUX36, LUX42 Installation Manual
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com/translations.
• 2287-980 Rev. L
2287-980 Rev. L • 4/16
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo LUX42

  • Page 1 See Table of Contents for location of additional Commonwealth Pour demander un exemplaire en français de ce Manuel of Massachusetts requirements. du propriétaire, visitez www.heatnglo.com/translations. Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 2: Table Of Contents

    C. Non-Combustible Material Installation ....31  = Contains updated information. Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 3: Installation Standard Work Checklist

    ____________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) = Contains updated information. 2287-982C 7/15 Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 4: Product Specifi C And Important Safety Information

    49,000 (0-2000 FT) LUX42 (NG) CANADA 44,000 (2000-4500 FT) Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 6: Getting Started

    Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 7: Framing And Clearances

    35-7/8 59-1/4 1505 39-7/8 1013 31-1/16 29-5/8 57-5/8 1464 3-7/8 54-15/16 1395 2-3/4 41-3/8 1051 10-7/8 16-1/8 Figure 3.1 Appliance Dimensions (LUX36) Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 8 1064 65-5/16 1659 45-7/8 1165 36-1/16 32-11/16 62-5/8 1591 3-7/8 59-15/16 1522 2-3/4 46-3/8 1178 10-7/8 16-1/8 Figure 3.2 Appliance Dimensions (LUX42) Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 9 36-13/16 IN. (935 mm) 40-11/16 IN. (1035 mm) 3-5/8 IN. 1-5/16 IN. (92 mm) (33 mm) Figure 3.3 Decorative Front Dimensions (LUX36) Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 10 41-13/16 IN. (1062 mm) 46-11/16 IN. (1186 mm) 3-9/16 IN. 1-1/4 IN. (91 mm) (32 mm) Figure 3.4 Decorative Front Dimensions (LUX42) Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 11: Clearances To Combustibles

    29-3/4 LUX36 Millimeters 1886 1511 2667 Inches 78-9/16 65-9/16 111-1/16 28-5/8 23-1/2 32-13/16 LUX42 Millimeters 1995 1665 2821 Figure 3.5 Appliance Locations Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 12 GRAY AREA NOTE: 2 X 4 HEADER CONFIGURATION 1 IN. FACTORY-SUPPLIED 1/2 IN. NON-COMBUSTIBLE BOARD = COMBUSTIBLES NOT ALLOWED Figure 3.6 Non-Combustible Zone Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 13: Constructing The Appliance Chase

    1549 1665 1321 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.7 Clearances to Combustibles (2 X 4 Construction) Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 14 ** 2 x 4 material must be framed down from 2 x 6 rough opening height B’ to rough opening height B. Figure 3.8 Clearances to Combustibles (2 x 6 Construction) Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L...
  • Page 15: Hearth Extension

    WOOD OR OTHER COMBUSTIBLE FLOOR OR PLATFORM Figure 3.11 Appliance Raised a Minimum of 3 Inches Above Combustible Surface. Non-Combustible Hearth Extension NOT REQUIRED. Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 16: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 17: Chimney Diagram

    2 sides beneath the fl oor. • Vinyl protection kits are required for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 18: Approved Pipe

    • Horizontal pipe installed level with no rise. DVP6 4-1/4 DVP12 8-1/2 DVP24 DVP36 25-1/2 Note: Model LUX42 (NG) must have 48 inches minimum DVP48 1219 vertical vent before attaching any elbow to the appliance. DVP6A 3 to 6 76 to 152 2-1/8-4-1/4...
  • Page 19: Vent Diagrams

    • LUX36 requires a minimum of 24 inches of vertical venting before attaching any elbow to the appliance. • LUX42 requires a minimum of 48 inches of vertical venting before attaching any elbow to the appliance. DO NOT attach elbow directly to the appliance.
  • Page 20 Figure 7.4. • LUX42 requires a minimum of 48 inches of vertical venting before attaching any elbow to the appliance. DO NOT attach elbow directly to the appliance.
  • Page 21 • LUX36 requires a minimum of 24 inches of vertical venting before attaching any elbow to the appliance. • LUX42 requires a minimum of 48 inches of vertical venting before attaching any elbow to the appliance. DO NOT attach elbow directly to the appliance.
  • Page 22 NOTE: Flue Restrictor ships in manual bag assembly. FLUE RESTRICTOR Figure 4.10 Flue Restrictor Installation Figure 4.9 Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 23 2 ft 610 mm 17 in. 432 mm • LUX42 requires a minimum of 48 inches of vertical venting before 3 ft 914 mm 3 ft 914 mm attaching any elbow to the appliance.
  • Page 24 4 ft 1.2 m 5 ft 1.5 m 9 ft 2.7 m • LUX42 requires a minimum of 48 inches of vertical venting before attaching any elbow to the appliance. 6 ft 1.8 m 12 ft 3.7 m DO NOT attach elbow directly to the appliance.
  • Page 25: Pvlp-Slp And Pvi-Slp Information

    This section provides specifi c detail for installation of closed. Adjust the baffl e by turning the screw located in the LUX36 and LUX42 models with approved power vent kits. motor enclosure. See Figure 4.12 and 4.13. Follow instructions included with the PVLP-SLP or PVI- SLP power vent kits.
  • Page 26: Vent Clearances And Framing

    (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 27: Ceiling Firestop/Floor Penetration Framing

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 28: Installing The Optional Heat-Zone Gas Kit

    Gas Kit instructions for the ® remaining installation steps. HEAT ZONE LOCATION ® LEFT AND RIGHT SIDES Figure 5.6 Heat Zone Cover Plate Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 29: Appliance Preparation

    NON-COMBUSTIBLE BOARD (NOT SHOWN) (NOT SHOWN) GLASS REFRACTORY GLASS REFRACTORY MEDIA MEDIA HEAT SHIELDS HEAT SHIELDS Figure 6.1 Shipping Location of Components Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 30: Securing And Leveling The Appliance

    • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. Figure 6.5. Heat Shields and Nailing Tabs in Installation Position Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 31: Non-Combustible Material Installation

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • See Section 10 for fi nishing materials guidelines. Figure 6.6 Installing Non-Combustible Facing Material Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 32: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 33: Secure The Vent Sections

    120º Figure 7.8 Align and Disassemble Vent Sections Figure 7.5 Securing Vertical Pipe Sections 120º Figure 7.6 Securing Horizontal Pipe Sections Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 34: Vertical Termination Requirements

    See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 35: Horizontal Termination Requirements

    Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 36 EXTERIOR VENT DEPTH FROM BACK OF APPLIANCE TO OUTSIDE SURFACE OF EXTERIOR WALL (SEE CHART BELOW) Figure 7.13 Venting Through the Wall Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 37: Electrical Information

    ACCESS THROUGH LEFT COLUMN ACCESS THROUGH FIREBOX SIDE GLASS PANEL GASKET COVER Figure 8.1 Junction Box Access Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 38 WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 39: Wiring Requirements

    FLAME IGNITER SENSE TO JUNCTION BOX (110V) MODULE RC100 BATTERY PACK 6V DC Figure 8.3 Intellifi re Pilot Ignition (IPI) Wiring Diagram Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 40: Gas Information

    C. Gas Connection A. Fuel Conversion • Refer to Reference Section 3 for location of gas line The LUX36 and LUX42 models are made for use with access in appliance. Natural Gas only. Conversion is not allowed. • Gas line may be run through knockout(s) provided.
  • Page 41: Air Shutter Setting

    LUX42 (NG) Left Burner Tube 1/8 in. Right Burner Tube 1/8 in. Rear Burner Tube 1/4 in. Center Burner Tube 1/4 in. Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 42: Finishing

    fi replace opening. 3/4 IN. Figure 10.4 Top/Side Finishing Templates Installed Figure 10.1 Side Finishing Template Bend - LMOD Decorative Fronts Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 43: Facing Material

    0 IN. Figure 10.6 0 in. NON-COMBUSTIBLE BOARD Figure 10.5 Non-combustible Facing Diagram MODEL LUX36 1549 57-5/8 1464 LUX42 1702 62-5/8 1591 Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 44: Mantel And Wall Projections

    Note: All measurements in inches. Note: Measurement is taken from top of the opening, NOT the top of the fi replace. Figure 10.10 Non-Combustible Mantel Allowance Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 45: Decorative Fronts

    BOARD DECORATIVE FRONT TYPE 3/4 IN. 1-1/4 IN. LMOD 1 IN. 3-1/4 IN. Figure 10.12 Required Clearance for Inside Fit Decorative Fronts Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 46: Appliance Setup

    Figure 11.2 Glass Clip Tool Location technician. See chart below for glass assembly weights. LUX42 MODELS: It is recommended that Glass in- 2. To disengage bottom glass clips, position the glass stallation and removal be performed by two qualifi ed clip removal/installation tool parallel to the fl...
  • Page 47 The LUX36 has three tabs and the LUX42 has four tabs. If the glass is not centered, it can not be installed properly. See Figure 11.5. 4. Install fi xed glass assembly by lifting it up and sliding it into the top retaining rail.
  • Page 48: Remove The Shipping Materials

    RIGHT LEFT LUX36 26-5/8 IN. 23-5/8 IN. LUX42 31-5/8 IN. 29-5/8 IN. Figure 11.9 Refractory Glass Panels Figure 11.12 Glass Refractory Installed Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 49: Media Placement

    Do not use more than 20 pounds of media in LUX36 or 24 opening. See Figure 11.15. Store the rock media pounds of media in LUX42. The LUX36 includes two 10 placement jig for later use. pound bags of media. The LUX42 includes one 10 pound bag and one 14 pound bag of media.
  • Page 50: Burner Tube Removal

    • Adjust shutter settings as required. • Reverse removal procedure to reinstall burner tubes Figure 11.17 Remove Three Plates and log assembly. Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 51: Reference Materials

    12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 12.1 DVP Vent Components Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 52 DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 12.2 DVP Vent Components Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 53 (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 12.3 DVP Vent Components Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 54 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profi le Cap Figure 12.4 Vent Components Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...
  • Page 55 Use if the PVLP-SLP is installed in a high traffi c area. PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.5 PVLP-SLP Vent Components Heat & Glo • LUX36, LUX42 Installation Manual • • 2287-980 Rev. L 2287-980 Rev. L • 4/16...
  • Page 56: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2016 Heat & Glo • LUX36, LUX42 Installation Manual • 2287-980 Rev. L • 2287-980 Rev. L • 4/16...

This manual is also suitable for:

Lux36

Table of Contents