Tip 3-4. Inspect WATER HOSE
Check Point
Step 1
①
Disassemble R room DOOR-L UPP
COVER
②
Inspect WATER HOSE bending
③
Inspect TUBE-FITTING direction
changing
Water direction
④
Inspect inner TUBE-FITTING SPRING failure
Step 2
①
Disassemble the Hose of Dispenser side.
②
Replace the Door when water comes
through hose from Cabinet side, because it
is hose freezing inner door and blocking.
Step 3
①
Disassemble R room Case VEG
②
Disassemble ASSY Case Filter Tank
③
Inspect Water Hose bending
Inspect WATER HOSE LINE
NG
Door Part
disassemble
- 45/65 -
OK
Hose