Tip 1-1. Inspect Display "Ice Type / Water" selecting
Check Point
Step 1
①
Check for
②
Check
"Ice Type/Water"
- If it is normal Inspect "Tip 1-2"
- If it is abnormal Inspect Step 2
Step 2
①
Check PANEL PBA WIRE HARNESS
Pin connection / switching
- Inspection of 1~5Wire
Verify that the wires are in
the correct order in the connector
①
Disassemble the HINGE-UPP COVER, check
the WIRE HARNESS Pin connection/switching
connection and verify the correct sequence
- Inspect BLK / BRN / RED / ORG / YEL
Wire
Step 3
①
Disassemble Main PBA Cover in the back
Inspect CN50 ①~⑤Wire Pin contacting and
switching
- BLK / BRN / RED / ORG / YEL Verify that
the wires are in
the correct order in the connector
①
If there is no problem on all,
- Replace the PANEL PBA
Check the "Ice Type/Water" Key selecting operation.
"Child
Lock" icon
Key.
- 4/65 -
CN 50