Error-code :
C-Fan Motor FG SIGNAL ERROR
Block
①
Inspect UNIT COMP C-Fan
- Inspect CONNECTOR No.1~3 Pin contact/switching
②
Inspect Fan Motor FG output : Main PBA
rotate
-
Normal : DC 2~4V
-
Failure : DC 2V↓ Wire Open inspection Replace Fan
CONNECTOR
Main PBA
23 E
CN 76
Back to List
CN76 No.9(BLU)+1(GRY) when Fan
※ Wire inspection
①
Inspect Fan Motor
- Inspect CONNECTOR
No.3(WHT) + Main PBA
CN76 No.9(BLU) WIRE OPEN
- Inspect CONNECTOR
No.2(REL) + Main PBA CN76
No.5(S/BLU) WIRE OPEN
- Inspect CONNECTOR
No.1(BLK) + Main PBA CN76
No.1(GRY) WIRE OPEN
①
Inspect normal condition
after replace it
Measure Main PBA CN76
No.1(GRY)+9(BLU) DC
voltage on CONNECTOR
contact and POWER ON
condition (Fan ON)
Normal: Measure DC 2~4 V
Failure : DC 2V↓, 4V↑
- 27/65 -
1: GND(BLK)
2: VCC(RED)
3: F G (YEL)