Error-code :
FF-Fan Motor FG SIGNAL ERROR
Block
①
Inspect the FF Room Fan
- Contact CONNECTOR No.1~3 Pin/
switching
②
Inspect Fan Motor FG output : When Main PBA
Fan rotate
-
Normal : DC 2~4V
-
Failure : DC 2V↓ Inspect Wire Open Replace Fan
CONNECTOR
Main PBA
22 E
CN 76
Back to List
CN76 No.8(RED)+No.1(GRY)
※ Inspect the Wire
①
Inspect Fan Motor
- Inspect the CONNECTOR
No.3(WHT) + Main PBA
CN76 No.8(RED) WIRE OPEN
- Inspect the CONNECTOR
No.2(REL) + Main PBA CN76
No.4(ORG) WIRE OPEN
- Inspect the CONNECTOR
No.1(BLK) + Main PBA CN76
No.1(GRY) WIRE OPEN
①
Inspect normal condition
after replace it
Measure Main PBA CN76
No.1(GRY)+No.8(RED) DC
voltage on CONNECTOR
contact and POWER ON
condition(FAN ON)
Normal: Measure DC 2~4 V
Failure : DC 2V↓, 4V↑
- 26/65 -
1: GND(BLK)
2: VCC(RED)
3: F G (YEL)