Step 3
(DEFROST SENSOR)
No freezing on the bottom of EVAP,
DEFROST SENSOR have ice.
Inspection and replace DEFROST SENSOR
open.
Step 4
(DEFROST SENSOR Sensing location
problem)
No freezing on the bottom of EVAP, EVAP top
+DEFROST SENSOR part don't have
freezing
Move the location of DEFROST SENSOR to
freezing part.
Step 6
(HEATER location problem)
When freezing on EVAP BOTTOM
- Improve DRAIN freezing.
Remove freezing with STEAMER
DRAIN HOLE blocking.
(Remove DRAIN freezing and foreign
substance)
DRAIN FIXER should be on CENTER.
Bending the HATER with hand into bottom.
- DRAIN HOLE should be
★ HEATER can not contact to PLATE.
Step 7
(Total inspection after defrost reparing)
Check the HEATER operation with forced
defrost operation after complete
Touch "Energy Saver+Fridge" for 8 sec at the
same time and operate
"Fridge" key 4 times after All LED off.
 Check the HEATER (Brown-wire) AC
voltage supplies when "beep" sounds.
Off with same way if there is no problem
Top+
and check
closed.
repairing.
"Fd"
with touching
- 53/65 -
EVAP Top + Sensor Freezing
Locate
Sensor
EVAP top freezing
+ No Sensor freezing
MOVE