Error-code :
INVERTER COMP Error
①
Check if overload by touching COMP.
- Operate normally after 8 min in the
case of re-operation.
CONNECTOR OPEN / INVERTER PBA problem
When the COMP is not hot
①
Inspect the COMP WIRE
②
Inspect the INVERTER PBA CN 04 3-WIRE
- Check U(BLU), V(PRP), W(BLK) OPEN order
③
Disassemble COMP RELAY COVER and check PIN
- Check U(BLU), V(PRP), W(BLK) OPEN order
COMP Locked problem(84)
When the COMP is hot
①
COMP problem /
Cycle Shield System problem
81 E
Operation failure
82 E
Comp Abnormal
83 E
current Detection
Motor Locked Over
84 E
85 E
Comp under voltage
86 E
81~86 E
Error
INVER PBA
IPM FAULT
RPM
Comp over
voltage
OPEN CHECK
CN 04
Failure reason
① Operate initial reoperation-rest 8min
② COMP U.V.W top SHORT
③ IPM PIN SHORT
④ INVERTER PBA failure
① Inspect Inverter PBA CN04
(Changed/OPEN)
② Inspect COMP WIRE(Changed/OPEN)
① Inspect COMP LOCKED / CYCLE
② COMP LOW rpm
③ Reoperation initial-rest 7min
④ INVERTER PBA
① Check power outlet
② INVERTER PBA
- 38/65 -
Back to List
CN 73
FUSE Check