Advertisement

Error-code :
FF-Defrost FUNCITON Error
Block
Inspect the BIMETAL (RED+BLK)
- Normal: 0Ω,
Measure Heater inspection resistance
Replace Heater
- Normal : 90~115Ω,
Inspect forced Heater On CONNECTOR voltage 105~125V
CONNECTOR
Main PBA
25 E
Failure: OPEN
- Failure : Open & 0 Ω
CN 70
CN 72
Back to List 
Open Part replacement
Measure Main PBA CN70
No.7(WHT)+CN72,No.3(GRY)
resistance
- Normal : 90~115Ω
-
※ Replace Heater /
BIMETAL
Measure Main PBA CN70
No.7(WHT)+CN72(GRY)
AC voltage after forced
defrost
- Normal : 105~125V
- Failure : NO Power
When all the parts are
normal, replace DEFROST
Sensor
- 29/65 -
Failure : Open & 0 Ω