4. Functions for failure diagnosis
4-2. Display function of Communication error
1-1) If there is no answer for 10 seconds after the panel micom received the requirement of
communication, "Pc - Er" display on the panel PCB will be ON/OFF alternately until the
communication error is canceled. (0.5 sec ALL ON, 0.5 sec ALL OFF alternately)
2-1) "OP - Er" code is repeatedly ON/OFF until Option error settles down.
⇀
70