Typical symptoms of these environments are:
Frequent scanner resets
Scanner occasionally loses power (due to host initiated shutdown)
Occasional host lockups.
Because multi-interface Miniscan Plus products are often exposed to these environments
due to the nature of scanner placement, they have been safeguarded as much as possible
to prevent physical damage. Despite design precautions, testing has shown that some USB
hosts cannot tolerate these environments. In this case, try placing a self-powered USB hub
close to the host, between the scanner and host, as a buffer to the host against the harsh
environment. This may not be a valid solution in all cases.

Technical Specifications

Table 5-3
provides the MS-220X technical specifications
Table 5-3. MS-220X Technical Specifications @ 23°C
Item
Power Requirements
Input Voltage
Scanning Current
Standby Current
MS-2204
MS-2207
V
Noise Level
cc
Laser Power
Scan Frequency: Horizontal
Scan Frequency: Vertical
Scan Rate
Print Contrast
Frame Rate
Skew Tolerance
Pitch Angle
5.0 VDC ± 10%
250 ± 30 mA typical
25 ± 5 mA typical
45 ± 5 mA typical
200 mV peak-to-peak max.
0.95 mW ± 0.1 mW, λ = 650 nm nominal
320 Hz ± 5 Hz
282 Hz ± 5 Hz
640 scans/sec.
Minimum 35% absolute dark/light reflectance differential
24 frames/sec. 12 Hz ±1 Hz (vertical)
o
± 15
from plane parallel to symbol
(see
Figure 5-3 on page
o
± 30
from normal (see
MS-220X Specifications
Description
5-8)
Figure 5-3 on page
5-8)