2.3 Image Scanning process

2.3.1 Structure and process of RADF
2.3.1.1 Cross-section view
1 Paper tray
2 Paper guide
3 Pick-up roller
4 Friction pad
5 Feed roller
6 Separation pad
7 Transfer roller
8 Pinch roller
44473001TH Rev.1
9 Regist roller
10 Pressure roller
11 Paper weight
12 Exit roller
13 Upper pinch roller
14 Lower pinch roller
15 Paper stcker
2.3.1.2 Electrical configuration
Electrical circuit configuration
Electrical control of the MFP is executed by the main controller circuit PCB.
The ASIC of the main controller circuit PCB interpret the input signals that are supplied from
sensors and the signals that are supplied from the externally connected equipment.
The ASIC output thesignals that drive the DC load devices such as motor, solenoid and
clutch in accordance with the specified timings.
The ADF relay circuit PCB do not contain the memory area.
The data such as service mode data is stored in the main controller circuit PCB.
ADF relay PCB
MOTIF
SNSIF
+24V
ADFM
ADFS
Main controller PCB
2. DESCRIPTION OF OPERATION
Motor
Sensor
Solenoid
Clutch
+3.3V