(2-3) Abnormal odor

Confirmation Items
(2-3-1) Locate the position with abnormal odor occurred.
Fuser unit
Take out the fuser and confirm
the odor.
Low-voltage power supply
Take out the low-voltage power
unit
supply unit and confirm the odor.
(2-3-2) Check the condition of fuser.
Life count of fuser
Confirm the life count of the fuser
by the maintenance utility.
Confirm whether the fuser is
Foreign confirmation of fuser
jammed with foreign body such
as paper inside.

(2-4) Slow starting time

Confirmation Items
(2-4-1) Check a fuser unit
Halogen lamp
Confirm the wattage of the
halogen lamp mounted in the
fuser.
(2-4-2) Check optional parts
Expansion memory
Reset the optional parts
(expansion memory) and recheck
the operation.
44473001TH Rev.1
Confirmation Tasks
Action at NG
Perform (2-3-2).
Exchange low-voltage
power supply unit
It may have abnormal
smell around a new
printer.
Remove the foreign
body.
Confirmation Tasks
Action at NG
Exchange for wattage
parts of the rated
voltage.
Exchange optional parts
(3) Error number and jam location at paper jam
Name
Reference Corresponding
Feed (front cover jam)
J5
Transport (paper feed jam)
J6
Exit (paper reject jam)
J7
Tray1 (paper feed jam)
J10
Paper size error (paper size
J12
error)
J7(EXIT)
J6(TRANSPORT)
EXIT sensor
7. TROUBLESHOOTING PROCEDURES
Jam release method
IN2, WR
Jam release method
IN1, IN2, WR,
Jam release method
EXIT
EXIT
Jam release method
IN1
Jam release method
IN1
Jam release method
J5(FEED)
IN2 sensor
J12(PAPER SIZE ERROR)
WR sensor
J10(TRAY1)
,
217 /