Oki Data CONFIDENTIAL
Item1
Item2
Item3
Password
ADF
AFE
(Back-side)
Parameter
Mechanical
Test
44473001TH Rev.1
Item4
Item5
Value
Change AFE (IC) register settings
Decimal number displayed,
decimal number set.
Maximum values vary with each
register.
→ Enter the register [n] setting
(n: 1 - 9). The current value is
read and displayed on the panel.
Settings values are changed,
configuration and reading
conducted, and the results read
are displayed on the panel.
R3 (03h)
R32 (20h)
R33 (21h)
R34 (22h)
R35 (23h)
R36 (24h)
R37 (25h)
R38 (26h)
R39 (27h)
R40 (28h)
R41 (29h)
R42 (2Ah)
R43 (2Bh)
ADF Test
Simplex/
Simplex
Duplex
Duplex
Speed
Color 300 x 300dpi
Color 300 x 600dpi
Color 600 x 600dpi
Mono
Execute
--Results--
Test no. xxx underway
Default
Default
Default
value
value
value
ODA
OEL
JP
Change AFE (IC) register settings (3 - 9 settings).
Then, read the document using PC Scan.
W : Display message showing that settings are complete.
R : Display read value.
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has been moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (30 cpm).
Display "Testing" during execution?
→ On the panel, indicate current number of executions using the message "Test no. xxx
underway."
5. MAINTENANCE MENUS