Finalizing The Installation - Travis Industries 36 ELITE-BI Xtrordinair Installation Manual

Hide thumbs Also See for 36 ELITE-BI Xtrordinair:
Table of Contents

Advertisement

F
INALIZING THE
P
30
AGE

Finalizing the Installation

!
ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been
treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid
wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia
solution, the gold face may develop a permanent tarnish when the acid evaporates over time.
!
WOOD SCRAP WARNING: Never burn wood scraps in the fireplace. Treated wood breaks down
the catalyst inside the fireplace, decreasing efficiency and increasing emissions.
1 Remove the set-up face using the #3 square drive included with the faceplate.
2 Make sure the firebrick is properly in place.
3 Install the log retainer using the included 1/8" allen wrench.
4 Install the baffle.
Serial # Plate
Place the log retainer into the holders. Tighten down the set screws in the holder with the included 1/8"
allen wrench. NOTE: The standard log retainer shown, the same instructions apply for the cast andiron
I
NSTALLATION
Use the #3 square driver included
with the faceplate to remove the 10
screws on the set-up face.
Place the baffle on the
brackets at the rear of the
firebox.
The firebrick
should be intact
and against the
walls of the
firebox.
Place the grate in the
center of the firebox
Door Switch (used
to automatically
turn the blower off
when the door is
opened)