Masonry Installation; Installation Preparation; Packing List; Fireplace Placement Requirements - Travis Industries 36 ELITE-BI Xtrordinair Installation Manual

Hide thumbs Also See for 36 ELITE-BI Xtrordinair:
Table of Contents

Advertisement

M
ASONRY
P
22
AGE

Installation Preparation

!
This installation should only be performed by a qualified mason familiar with constructing fireplaces
and the codes and requirements that apply.
!
Read this entire manual before installing the fireplace.
!
Failure to install this fireplace in accordance with all local codes and the requirements listed in this
manual may result in property damage, bodily injury, or even death.
!
Notify your insurance company before installing this fireplace.
!
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid Ð the qualified installer should follow the
procedure best suited for the installation.
!
Modifications of the fireplace (doors, blower, air inlet systems, damper control, or any other
component supplied by Travis Industries) or use of any component part not approved by Travis
Industries in combination with this fireplace system will void the listing and warranty.

Packing List

Shipped with the Fireplace:
¥
Installation Manual with Catalyst Warranty Card
¥
Grate
¥
Baffle
¥
Blower Assembly
¥
Ember Strip
¥
Log Retainer (includes allen wrench & instructions)
¥
Flex Duct w/ start collar Ð 3' Length, 6" Dia (For Blower)
¥
Fiberglass (for expansion buffer)
¥
6" Dia. Air Vent (& Storm Collar) for chase venting
¥
New Door Pawl & Heat Shield (For use with older doors)
¥
The fireplace is shipped with a lifting handle on each side. After the fireplace is in place, remove
these handles.

Fireplace Placement Requirements

¥
Fireplace should be located such that no doors,
drapes, furniture or other combustibles can be
placed close or swing closer than the minimum
36" clearance. Due to the high heat output of
this fireplace, choose a location away from
high traffic areas.
¥
Fireplace must be placed so the vents below
and above the glass do not become blocked
¥
Adjacent sidewalls must be a minimum 18"
from the side of fireplace

Hearth Requirements

¥
The hearth must be a minimum 1" thick of non-combustible material
¥
The hearth must extend 18" from the front of the faceplate and 8" to each side (52" wide)
¥
Hearth extension must be no higher than the bottom edge of the fireplace face plate.
I
NSTALLATION
Shipped with the Faceplate:
¥
Faceplate (two switch plate screws are attached)
¥
#3 Square Driver
¥
Switch Plate (includes blower rheostat)
¥
12 Faceplate Screws
Shipped with the Door(s):
¥
Owner's Manual
¥
Replacement Pawl (For use with 36A fireplaces)
¥
Four Washers
¥
Pair of Gloves
¥
Efficiency, Registration & Oregon DEQ Cards
¥
Touch-up Paint
18"