Corner Installation (minimum framing dimensions at 45°)
60 3/4"
Min.
25 "
Min.
Block-In Drying Time
¥
The block-in must dry for one month before using the fireplace. This will prevent the block-in from
cracking due to the heat generated from the fireplace.
Special Precautions
¥
In some states the block-in may require special construction to meet earthquake requirements. This
may include having to mortar the block-in to expanded metal and/or a tied down block-in
construction. Check with your local building department for requirements in your area.

Facing

¥
The facing must be made of a non-combustible material such as stone, brick, marble or tile. For thin
facing such as marble or tile 1/2" cement fiber board (see illustration above) must be used as a
backing to attach the facing material.
¥
Non-combustible facing must extend 4 1/2" from each side of the fireplace
¥
Non-combustible facing must extend 26" from the top of the fireplace
1/2" Sheetrock
Tile Or Marble Facing
B
-I
LOCK
19 1/2"
Edge of Faceplate
F r a m i n g
2" Minimum
4 1/2" Minimum (Flush Fit
Allowed With 1/2"
Non-Combustible Facing)
I
N
NSTALLATION
Required 6" Cooling Vent
(Optional Location)
2" Min.
3 1/2" Minimum
F i r e p l a c e
B l o c k
1/2" Cement
Fiberboard Must Be
Sealed To Block
(C
)
ONTINUED
Clearance From
Masonry Block
to Wall
43"
Fireplace
Face
Plate
1"
Fiberglass Insulation
Expansion Buffer
P
5
AGE