Chimney Requirements

¥
Use one of the following brands and type of chimney:
¥ Temco 82
Chimneys Part Numbers
Chimney Components
12" Chimney Section
18" Chimney Section
24" Chimney Section
36" Chimney Section
48" Chimney Section
Offsets
Flashing
Chimney Cap
Roof Support
Firestop Spacer
Chimney Connection to Fireplace
¥
The inner liner of the chimney attaches to the flue collar on the fireplace. The outer liner is left open
(with air space) directly above the block-in. Most chimneys will attach directly. If having difficulty,
use the Travis Industries chimney adapter built specifically for the 36 Elite-BI. This chimney
adapter accommodates the chimney brands listed in this section. Follow the directions below for
attaching the chimney adapter.
1) Center the adapter over the flue opening and push it down until it is fully seated.
2) Insert the inner liner of the chimney pipe into the inner liner of the chimney adapter. Certain
brands of chimney pipe will stop at the ledge, while others will insert beyond the ledge. When
the chimney pipe is fully seated and aligned, secure the chimney adapter to the chimney pipe
with three sheet metal screws. Seal any gaps with furnace cement (allow 24 hours to dry).
3) The outer liner of the chimney attaches to the stepped brackets on either the upper or lower step.
Secure the outer liner of the chimney pipe to the brackets with four sheet metal screws.
Use Four Sheet Metal
Screws to Attach the
Outer Liner Connector to
the Chimney Pipe.
Inner Liner (Ledge Along
Inside Accepts Different
Sized Chimney Pipes)
Outer Liner Connector
(Stepped Construction
Allows Different Sized
Chimney Pipes)
!
When the chimney system is fully installed, air should be allowed to pass into the space between the
inner and outer liners on the chimney adapter. This space allows proper ventilation for the fireplace
and chimney system. Failure to allow air into this space presents a fire hazard.
B
LOCK
¥ Superior TF8
Temco 82
Superior TF8
8212D
8218D
8224D
8236D
8248D
8232E
TF8-30, TF8-E30
8206F
8203D
8204S
---
-I
I
N
NSTALLATION
¥ FMI 8DM
¥ Marco 8D
FMI 8DM
TF8-12
12-8DM
TF8-18
18-8DM
---
24-8DM
TF8-36
36-8DM
TF8-48
48-8DM
30E-8DM
8-F6
6F8 or 12F8
TF8-CTO
RTL-8HT
8-54
38 RS
8FS-2
FS-8DM
(C
ONTINUED
Marco 8D
12 - 8D
18 - 8D
----
36 - 8D
48 - 8D
30E - 8D
12F - 8D
BT - 8D
12CPS - 8D
FS30 - 8D
Use the Upper or Lower
Hole Depending on the
Chimney Pipe Diameter
Connect Inner Liner to the
Chimney Pipe with Three
Sheet Metal Screws in the
Holes Provided
The Crimped End is
Inserted Into the
Flue Opening of the
Fireplace Xtrordinair
)
P
11
AGE

Advertisement

Table of Contents
loading

Table of Contents