3. USE AND MAINTENANCE
3.13 Heating Mode and Super Heating Mode
This unit has an integrated heater with the ability to produce heat even at very low outdoor
temperatures.
There are two heating modes which should be used according to different outdoor temperatures:
STANDARD HEATING MODE (outdoor temperature above 41°F)
SUPER HEATING MODE (outdoor temperature below 41°F)
The amount of energy used by the machine depends on which mode is used. Therefore users are
advised to read the following guide carefully and select the correct operating mode for the correct
outdoor temperature condition.
STANDARD HEATING MODE is recommended mainly in Late Spring / Summer / Early
Autumn when heating is required and outdoor temperatures tend to stay above 41°F.
This mode does not incorporate the on-board supplemental electric heater, but runs the
heat pump only. This mode is more energy efficient.
SUPER HEATING MODE is recommended in Late Autumn / Winter / Early Spring when
the standard heating mode is not suffice and temperatures tend to stay below 41°F. This
mode incorporates the standard heat mode as well as the additional on-board
supplemental electric heat. This mode requires more energy than the Standard heating
mode, as more energy is needed to power the electric heater.
...........................................................................................................................