7. Cooling or Heating Mode with Sleep Mode Auto Control

• When selecting the Cooling(
operation diagram is as following.
Cooling Mode with the Sleep Mode
• The setting temperature will be automatically raised by 2°F 30 minutes later and by 4°F 1 hour later.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP. +1°F
(Compressor ON)
SETTING TEMP. -1°F
(Compressor OFF)
INDOOR FAN SPEED
COMPRESSOR
Heating Mode with the Sleep Mode(only Heating Model)
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP. +6°F
(Compressor OFF)
SETTING TEMP.
(Compressor ON)
INDOOR FAN SPEED
COMPRESSOR
) or the Heating(
30 minutes
More than
3 minutes
Low
Low
ON
OFF
More than
3 minutes
Med
Low or OFF
ON
OFF
- 20 -
) combined with the Sleep Mode Auto Control(
2°F
More than
3 minutes
Low
Low
ON
OFF
More than
3 minutes
Med
Low or OFF
ON
OFF
), the
30 minutes
2°F
Low
ON
More than
3 minutes
Med
Low or OFF
ON
OFF

Advertisement