4. DO NOT USE ABRASIVE PADS OR OVEN
CLEANSERS CONTAINING CITRIC ACID
ON ENAMELLED SURFACES. ENSURE
THAT THE CLEANSER MANUFACTUR-
ERS INSTRUCTIONS ARE ADHERED TO.

GLASS CLEANING

The glass will self clean when there is sufficient heat
generated by the burning fuel. If a build-up of cre-
osote occurs on the glass it may be due to draft con-
ditions, poor quality fuel or very low burning for a
long time. It is best to clean the glass when it is
thoroughly cooled.

GLASS REPLACEMENT

(a) Open the front door fully.
(b) Remove the four corner screws and clips
and carefully remove the broken glass.
(c) Clean the glass recess in the door.
(d) Attach adhesive thermal tape to the
perimeter of the replacement glass.
(e) Place the thermal tape side of the glass into
the door recess and replace the four corner
clips.
(f) Tighten screws.
(g) Replace glass only with ceramic glass 5mm
thick.

DATA PLAQUE POSITION

The data plaque is positioned at the back of the
stove, See Fig.21.
Fig.21
Fig.20

CO ALARM

Waterford Stanley recommend the fitting of a CO
Alarm in the same room as the appliance, this is a
requirement under UK Building Regulations.
Further guidance on the installation of a carbon
monoxide alarm is available in BS EN 50292:2002
and from the alarm manufacturers instructions.
Provision of an alarm must not be considered a
substitute for either installing the appliance
correctly or ensuring regular servicing and
maintenance of the appliance and chimney
system.
WARNING:-
If the CO Alarm sounds unexpectedly:-
1. Open Doors and windows to ventilate the
room and then leave the premises.
2. Let the fire go out.