Page 1
TARA ELECTRIC STOVE Focal Point Electric Stove with Log effects incorporating a 1.2kW Fan Heater. INSTALLATION & OPERATING INSTRUCTIONS The complete installation must be done in accordance with current Standards and Local Codes. It should be noted that the requirements and this publication may be superseded during the life of the stove.
Page 3
IMPORTANT When using electrical appliances, basic pre- INSTRUCTIONS cautions should always be followed to reduce the risk of fire, electric shock and injury to per- PLEASE RETAIN THIS USER’S GUIDE sons, including the following: FOR FUTURE REFERENCE Read all instructions before using this stove. This stove is hot when in use.
Page 4
RATED VOLTAGE: 120 V 60Hz Ac RATED CURRENT: 11 AMPS LAMP RATING: Two 120V, 60 Watt Clear Candle OUTPUT: Low Heat 0.6 kW High Heat 1.2 kW FAN MOTORS: 1 x 6.5w / 1 x 2.5w SERIES: TARA ELECTRIC STOVE SPECIFICATIONS...
OPERATION the heater if; for any reason; it overheats. Should the cut-out operate, determine the reason for the The controls are located on the lower right hand overheating before resetting the cut-out. To reset side of the stove. See Fig. 1. the cut-out, switch off or unplug the heater for a few minutes, after which normal operation may be Fig.1...
VOLTAGE LAMP All enquiries for service should be directed in the MODEL TARA LOG EFFECT: Refit the fuel effect first instance to the retailer from whom your prod- panel complete with fixing screws, ensuring that uct was purchased.
Page 7
Manufactured by Waterford Stanley Ltd., Unit 210, IDA Industrial Estate, Cork Road, Waterford, Ireland. Tel: (051) 302300 Fax (051) 302315 Rev: 005DP 071001...