Step 3. Running System Verification; Step 4. Additional System Verification - IBM Intellistation POWER 9112 265 User Manual

Hide thumbs Also See for Intellistation POWER 9112 265:
Table of Contents

Advertisement

v If you need to change any settings, record the normal settings, and make sure
v Return to substep 5 when you finish checking the attributes.
5. Turn on the power.
a. When the keyboard indicator displays, press the numeric 5 key on the keyboard
b. Enter requested passwords.
c. Follow any instructions to select a console.
6. When the diagnostic operating instructions display, go to "Step 3. Running System
Verification". If you are unable to load the diagnostics, go to "Problem Determination
When Unable to Load Diagnostics" on page 152.

Step 3. Running System Verification

When the Diagnostic Operating Instructions display, do the following to run system
verification:
1. Press Enter.
2. If the terminal type has not been defined, you must use the Initialize Terminal
option on the Function Selection menu to initialize the operating system
environment before you can continue with the diagnostics.
3. To do a general checkout with minimal operator action, select the Diagnostic
Routines option on the Function Selection menu.
To do a more complete checkout including the use of wrap plugs, select the
Advanced Diagnostics option on the Function Selection menu. The advanced
diagnostics are primarily for the service representative; they may instruct you to
install wrap plugs to better isolate a problem.
4. Select the System Verification option on the Diagnostic Mode Selection menu.
5. To run a general checkout of all installed resources, select the All Resource option
on the Diagnostic Mode Selection menu.
To check one particular resource, select that resource on the Diagnostic Mode
Selection menu.
6. Go to "Step 4. Additional System Verification".

Step 4. Additional System Verification

The checkout programs end with either the Testing Complete menu and a message
stating No trouble was found, or the A Problem Was Detected On (Time Stamp) menu
with a service request number (SRN).
To perform additional system verification, do the following:
1. Press Enter to return to the Diagnostic Mode Selection menu.
142
User's Guide
that the terminal attributes are set to work with the diagnostics. If needed, see
Appendix C, "General Attributes Required When Using a TTY Terminal" on
page 163.
to load the standalone diagnostics or the numeric 6 key on the keyboard to load
the online diagnostics.

Advertisement