INSTALLATION

EXHAUST DUCTING OPTIONS

There are two ducting options available for this appliance, these are a Window installation or an optional Semi-
permanent wall installation.
DO NOT over extend the exhaust duct.
Over extension of the exhaust duct can lead to kinking.
IMPORTANT
Kinked ducting causes air flow restrictions and lowers the
efficiency of the appliance.
Keeping the exhaust duct as short as possible avoids this
issue.

WINDOW INSTALLATIONS

The window kit has been designed to fit most standard vertical and horizontal window applications. There may be 
some cases where you may need to modify some aspects of this installation procedure for certain window types. 
Minimum and maximum horizontal / vertical window opening dimensions:
Horizontal
Window
Installation
A
1.
Once a suitable window has been chosen, fit the Adjustable Slider Kit (14) into the window areas and fix the 
length of the kit using the supplied slide lock nut and bolt.
It is recommended to place a length of foam draft sealing strip along the top and bottom edges of
the kit or the inside the window opening to form a seal.
NOTE
2.
Connect the Window Exhaust Duct Adaptor (15) to the Adjustable Slider Kit (14).
Rinnai
A
14
Vertical
Window
Installation
A - Minimum = 675mm
A - Maximum = 1250mm
Slide lock nut and bolt
Insert window
Foam seal
exhaust duct
adaptor here
Portable Room AC OIM