Table 10 - Fireplace Framing Dimensions
Model
53-3/4
42"
1366
65-3/4
54"
1670
*with 1/2" recess for flush framing
NOTE: Illustration provided for dimensions. Fireplace must be adequately
framed and supported with 2 x 4, or larger building materials.
a. Required frame opening width (1/2 of a = horizontal centerline of
fireplace and vent framing opening)
b. Required frame opening depth with 1/2" (13mm) thick wall finish
material (for other wall finish thicknesses, adjust frame opening depth
and nailing flanges accordingly)
c. Minimum frame opening height (from base of appliance to header)
d. Minimum height from appliance base to vertical centerline of horizontal
termination vent pipe (with 6" [54" models] or 12" [42" models]
straight vent section and 90° elbow off appliance vent collar)
NOTE: The vertical centerline of the horizontal termination vent pipe is NOT the same as
the vertical centerline of the vent frame opening because of firestop/spacer offset.
e. Minimum height from appliance base front to ceiling
f. Mounting platform
NOTE: Mount on a fully supported platform extending full width and depth of unit.
Table 11 - Fireplace Framing Specifications—Corner Installation with Horizontal Termination
Model
A
53-3/4"
42"
(1365 mm)
65-3/4"
54"
(1670 mm)
NOTE: Back wall of chase/enclosure (including finishing materials) shown.
Table 12 - Fireplace Dimensions
Top Spacer (shipped flat)
B
Top View
Model
A
42"
26-7/8" (683 mm)
54"
32-1/2" (826 mm)
NOTE: Assemble top standoffs before installing fireplace.
18
a
b
57-3/4*
20-1/2
21*
1467*
521
533*
69-3/4*
20-1/2
21*
1772*
521
533*
B
C
94-3/4"
67"
47-3/8"
(2407 mm)
(1702 mm)
(1203 mm)
106-3/4"
75-1/2"
53-3/8"
(2711 mm)
(1917 mm)
(1356 mm)
11 7/8
11 7/8
11 7/8
(302)
(302)
(302)
A
b
53-3/4" (1366 mm)
32-1/2" (826 mm)
65-3/4" (1670 mm)
36-3/8" (924 mm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
c
d
42
43-1/2*
50-3/8
1067
1105*
1280
46-3/4
48-1/4*
48-1/4
1184
1226*
1226
Note: Illustration provided for dimension information only. Fireplace must be adequately framed and supp
A = Required frame opening width. (1/2 of A = horizontal centerline of fireplace and vent framing opening.)
B = Required frame opening depth with 1/2" (13mm) thick wall finish material. For other wall finish thickness
D
E
adjust frame opening depth and nailing flanges accordingly (see "Unit Nailing Flanges" section).
25-1/8"
C = Min. frame opening height (from base of appliance to header).
(638 mm)
D = Min. height from appliance base to vertical centerline of horizontal termination vent pipe (with 6" straig
section and 90° elbow off appliance vent collar). (Note: Vertical centerline of horizontal termination ven
29-3/8"
is NOT the same as vertical centerline of vent frame opening. ecause of firestop/spacer offset.
(745mm)
See "Exterior Wall Opening Framing" section.)
E = Min. height from appliance base (front) to ceiling.
F = Mounting platform (Note: Mount appliance on fully supported platform extending full width and depth
D
(229)
Front View
C
D
44-1/8" (1121 mm)
56-1/8" (1426 mm)
e
65
(1651)
d
c
b
a
E
C
A
B
Table 13 - Viewable Glass
9
42" models
(229)
20 1/2
9
9
20 1/2
(229)
(521)
(521)
54" models
Table 14 - Surround Dimensions
E
C
42" models
9 7/8
9 7/8
(251)
(251)
54" models
Right Side View
Table 15 - Vent Collar
E
All models
15-11/16" (398 mm)
NOTE: Before installing fireplace, nailing
19-5/8" (498 mm)
flanges MUST be adjusted according to
finish (cleanface or surround) and wall
finish material thickness. This is critical
to ensure proper fireplace location,
especially if installing optional surround
and bezel.
Installation
900077-00, 07/2015
10-1/2
(267)
12-1/8
(308)
f
*
1/2 of A
inches
(millimeters)
7 (178)
D
40" W x 10-1/2" H
1016 mm x 267 mm
51" W x 14-3/4" H
1295 mm x 375 mm
55" W x 23-3/4" H
1397 mm x 603 mm
67" W x 27-11/16" H
1702 mm x 704 mm
4-1/2" inner x 7-1/2" outer