Drl6500 linear direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRL6500 Linear Direct-Vent Gas Fireplaces
Table 21 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits
NOTE: See Figure 29 for wall thickness ranges when using SV4.5HT-2 termination kit.
Horizontal Vent Figures/Tables
NOTE: Secure Vent
terminal may also be used.
NOTE: If the parameters of your vent run fall outside the parameters described herein, consider installing the Power Vent Kit.
NOTE: Two (2) 45° elbows may be used in place of one (1) 90° elbow. The same rise to run ratios, as shown in the
venting figures for 90° elbows, must be followed if 45° elbows are used.
NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined
run in a straight (no dips), slightly elevated plane of approximately 1/4" per 1 ft (20 mm per 1 m).
NOTE: SV4.5VF (Secure Vent), SF4.5VF (Secure Flex) firestop/spacer must be used any time vent pipe passes
through a combustible floor or ceiling. SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) firestop/spacer must be used
any time vent pipe passes through a combustible wall.
Do not join separate sections of concentric flexible vent together.
Table 22 - Top Vent—One 90° Elbow
Maximum total H
feet
meters
2
4.5
6
7.5
9
15
Total H = 15 ft (4.572 m) maximum
Total H + Total V = 60 ft (18.3 m) maximum
Install the U-shaped vent restrictor in any vent run with more than 6-1/2 ft of
vertical rise. See Page 20 for more information.
Small square termination (SV4.5HT-2) shown.
See Table 21 as an aid in venting component selection for a particular range of exterior wall
thicknesses.
15 ft total horizontal vent run requires a minimum of 10 ft total vertical vent.
Vertical firestop/spacer must be used anywhere vent pipe passes through a combustible floor or ceiling. Horizontal firestop/
u
spacer must be used anywhere vent pipe passes through a combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance collar. A minimum 12" pipe section must be used between the fireplace
collar and a 90° elbow.
32
Vent Components Required
Termination Kit Only
Termination Kit and 6" Vent Section (SV4.5L6)
Termination Kit and 12" Vent Section (SV4.5L12)
Termination Kit and Telescopic Section (SV4.5L12)
rigid vent pipe and terminal are shown in the figures. Secure Flex
®
Minimum total V
feet
0.610
1
1.372
3
1.829
4
2.286
5
2.743
6
4.572
10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
meters
0.305
0.914
1.220
Horizontal
Termination
1.524
1.729
Horizontal Firestop/
Spacer
3.048
Exterior wall Thickness
6 to 9-1/4" (152 to 235 mm)
10-3/4 to 14" (273 to 356 mm)
16-3/4 to 20" (426 to 508 mm)
11-3/4 to 20" (299 to 508 mm)
flexible vent pipe and
®
H
Vertical Firestop/
Spacer
u
u
Installation
900077-00, 07/2015
V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drl6554ten

Table of Contents