Communicator Formats; Reporting Events To Phone #1, #2, & #3 - GE NetworX NX-4 Installation And Startup

Control/communicator
Hide thumbs Also See for NetworX NX-4:
Table of Contents

Advertisement

DATA
FORMAT
0
Local
1
Universal 4+2
2
3+1 fast (or 4+1)
3
Reserved
4
Pager
5
3/1 or 4/1 slow
6
3/1 or 4/1 slow
7
3/1 or 4/1 fast
8
3/1 or 4/1 fast
9
3/1 or 4/1 fast with
parity
10
3/1 or 4/1 fast with
parity
11
4+2 express
12
4+2 fast
13
Ademco Contact ID
14
SIA
15
Custom format
Location 4 is used to select which events are reported to Phone #1. If dual or split reporting is not desired, location 4
should be used to select all events to Phone #1. If dual or split reporting is desired, location 4 should be used to select
only those events that should be reported to Phone #1. If no events should be reported to Phone #1, location 4
should be programmed as "0" (disabled).
LOCATION 4 - EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection data)
Segment 1:
1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut, Bell Cut Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
Segment 2:
1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Over-current and Restore.
3 = Wireless Sensor Missing and Restore.
4 = Wireless Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Reserved.
8 = Reserved.
FORMAT SELECTIONS
Communicator is disabled
Two digit event code 1800hz transmit 2300hz handshake double round parity
40pps
One digit event code 1900Hz transmit 1400Hz handshake double round parity
20pps
Reserved
2 digit event code DTMF transmission
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
2 digit event code DTMF transmission
Two-digit event code 1900hz transmit 1400hz handshake double round parity 20
p.p.s.
DTMF (see pages 33-34)
FSK (see pages 33-34)
(See location 18, page 16)
REPORTING EVENTS TO PHONE NUMBER 1
DESCRIPTION
NX-4 Control