GE NetworX NX-4 Installation And Startup page 8

Control/communicator
Hide thumbs Also See for NetworX NX-4:
Table of Contents

Advertisement

NX-4 Control
Local Programming Lockout
This feature will disable programming of all locations or specified locations from the keypad. (Loc. 21, page 16)
Log Full Report
A report can be sent to the central station when the event log is full. (Loc. 37, page 17)
Lost Clock Service Light
The NX-4 can be programmed to illuminate the "Service" LED when the internal clock has an invalid time due to
power loss. (Loc. 37, page 17)
Manual Test
The NX-4 can be programmed to perform a bell and/or communicator test when [r]-[4] is entered while the
system is in the disarmed state. (Loc. 37, page 17)
On Board Zone Disable
The four zones on the NX-4 panel can be disabled in order to have a completely wireless alarm system. (Loc. 37,
page 17)
Program Code
The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] when using a 4-digit code or, if the 6-digit
option is used, the default is [9]-[7]-[1]-[3]-[0]-[0]. The program code can also be used as an Arm/Disarm code.
If used as an Arm/Disarm code, and open/close reports are sent, the user code will be 255. (Loc. 43, page 19)
Quick Arm Feature
The NX-4 has a one button "Quick Arm" feature which can be used to arm the system by pressing the [Exit] key or
the [Stay] key. If closing reports are sent, the user code will be 98. (Loc. 23, page 16)
Recent Closing
If enabled, the NX-4 will send a "Recent Closing Report" to the central station if an alarm occurs within 2 minutes
after the panel is armed. The user number that armed the system will also be sent. (Loc. 23, page 16)
Re-exit
The NX-4 has the ability to restart the exit delay for a quick exit without disarming the system by pressing the
[Exit] key while the system is armed. (Loc. 23, page 16)
Shutdown
This mode will cause the keypads to turn off all LED=s, except the "Power" LED, and not accept keypresses. (Loc.
21, page 16)
Siren Blast For Arming
The NX-4 can be programmed to give a one-second siren blast when the panel is armed, at the end of the exit
delay, or when the central station receiver acknowledges the closing report. It can also give one blast for wireless
arming and two blasts for wireless disarming. (Loc. 37, page 17)
Siren Supervision
The NX-4 has a ASiren Supervision@ circuit that will constantly monitor the siren on the NX-4 and can be
programmed to report if the wires are cut. (Loc. 37, page 17)
Silent Exit Option
The exit delay can be silenced by pressing [r]-[Exit] before arming the control panel, or when using the re-exit
feature.
Start/End Programming and End Downloading
A report can be sent when local programming is started and ended. A report can also be sent when a download
session ends. (Loc. 37, page 17)