Segment 2- Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8 to make
the designated number of attempts to Phone #2 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8 to stop trying to communicate after the designated
number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the NX-8 to
make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two attempts to
Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
DATA
FORMAT
0
Local
1
Universal 4+2
2
3+1 fast (or 4+1)
3
Reserved
4
Pager
5
3/1 or 4/1 slow
6
3/1 or 4/1 slow
7
3/1 or 4/1 fast
8
3/1 or 4/1 fast
9
3/1 or 4/1 fast with parity
10
3/1 or 4/1 fast with parity
11
4+2 express
12
4+2 fast
13
Ademco Contact ID
14
SIA
15
Custom format
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based
on the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should
be reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired,
and the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select
those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations
should be programmed as "0" (disabling all options).
LOCATION 4 - EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection data)
Segment 1:
1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
14

COMMUNICATOR FORMAT SELECTIONS

Communicator is disabled
Two digit event code 1800hz transmit 2300hz handshake double round parity
40pps
One digit event code 1900Hz transmit 1400Hz handshake double round parity
20pps
Reserved
2 digit event code DTMF transmission
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
2 digit event code DTMF transmission
Two digit event code 1900hz transmit 1400hz handshake double round parity 20
p.p.s.
DTMF (see pages 52-53)
FSK (see pages 52-53)
(See location 18, page 18)