Mode
413
Bit:
Bit
Feature
7 – 6
Selection of fax (G3-1) output tray✽
5 – 4
Selection of output tray for com-
puter printouts
3
2
Selection of copy output bin
1
Selection of fax (G3-1) output bin
0
Selection of output bin for computer
printouts
Mode
432
Bit:
Bit
Feature
7 – 0
Wait time for computer printing with
full memory (M)
Note: Features marked with asterisks can be specified by the user. ✽ indicates screen settings.

Factory Setting

7
6
5
4
3
2
1
0 0 0 0 0 1 0 0
Logical Value
0
1
Bit 7-6:
00
1st paper output
tray
01
2nd paper output
tray
10
Additional bin
11
Do not specify this
setting.
Bit 5-4:
00
1st paper output
tray
01
Sorted copy tray
10
3rd paper output
tray
11
Do not specify this
setting.
Fixed
Do not change this setting.
Bin 1
Bin 2
Specifies the copy output bin when the job sepa-
rator is installed.
Bin 1
Bin 2
Specifies the bin that fax (G3-1) prints are fed into
when the job separator is installed.
Bin 1
Bin 2
Specifies the bin that computer printouts are fed
into when the job separator is installed.
Factory Setting
7
6
5
4
3
2
1
0 0 0 0 0 1 0 1
Logical Value
0
1
Bit 7-0:
00000000
Erase immediately
00000001
1 minute
00000101
5 minutes
00011110
30 minutes
Others
Do not specify
these settings.
S-7
0
HEX:04
Description
Specifies the tray that fax
(G3-1) prints are fed into
when a finisher is installed.
The 3rd paper output tray is
available only if the additional
bin kit is installed.
Specifies the tray that com-
puter printouts are fed into
when a finisher is installed.
The 3rd paper output tray is
available only if the additional
bin kit is installed.
0
HEX:05
Description
Specifies the wait time for
computer printing when the
memory is full (M)
Setting range: 0 minutes, 1 to
30 minutes
(1-minute intervals)
Erases the computer print
job after reaching the speci-
fied wait time when the mem-
ory is full.
Setting conditions for bits 7
through 4 of mode 320,
around-the-clock monitoring
timer (t1), and bits 3 through
0 of mode 320, around-the-
clock monitoring timer (t2):
Each must be set so that
t2
t1
M.

Advertisement