Connection Of Buzzer And/Or Remote Display - Furuno FR-8045 Installation Manual

Hide thumbs Also See for FR-8045:
Table of Contents

Advertisement

4. OPTIONAL EQUIPMENT
4.2

Connection of Buzzer and/or Remote Display

You will need the cables shown below to connect the optional external buzzer and re-
mote display.
• Two-way cable MJ-A10SPFW0001 +R
• MJ-A7SPF0007-050C
• MJ-B24LPF0010-xxx+R (000: 100, 200, or 300)
Display unit
RDP-154
Connection Port
OPTION
External buzzer
When a target enters, or exits, in the target zone, the optional external buzzer gives a
loud alarm.
Type
Code No.
Name
Buzzer
Cable tie
Heat-shrink-tube
Double-sided tape
Attach the two-way cable and MJ-A7SPF0007-050C cable to the OPTION port at the
rear of the display unit. See the above figure.
1. Cut the NH connector at the end of the external buzzer cable to an acceptable
length.
2. Solder the external buzzer cable to the MJ-A7SPF0007-050C cable as shown be-
low. Before you solder the cores, cut the heat-shrink-tube in half and set the tubes
to the cores of the cable. Solder the cores, then set the tubes on the soldered
point.
MJ-A7SPF0007-050C
3. Fasten the buzzer with the double-sided tape or two self-tapping screws (3x15 or
3x20, local supply).
MJ-A10SPFW0001+R * (0.2 m)
MJ-A7SPF0007-050C (5 m)
MJ-10P
MJ-10P
*: This cable is not required to connect the remote display only.
OP03-21
000-030-097
Type
PKB42SWH2940
000-153-221-10
CV-70N
000-162-185-10
3x0.25 BLK
000-165-283-10
9760
000-800-851-00
Cut other cables off, and wrap here with tape.
MJ-7P
MJB24P
MJ-B24LPF0010-xxx+R (10/20/30 m)
(xxx: 100, 200 or 300)
Code No.
Qty
1
4
1
1
Red
Solder
Black
33
External buzzer
Remote Display
Comment
One NH connector attached
40 mm
25 mm × 25 mm
External buzzer

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-8125Fr-8065Fr-8255

Table of Contents