Connection Of Buzzer And/Or Remote Display - Furuno 1935DISP Installation Manual

Table of Contents

Advertisement

4.2

Connection of Buzzer and/or Remote Display

You need the cables shown below to connect the optional external buzzer and remote display.
• Two-way cable MJ-A10SPFW0001+R
• MJ-A7SPF0007-050C
• MJ-B24LPF0010-xxx+R (xxx: 100, 200 or 300)
Display unit
RDP-152
Connection Port
External buzzer
When a target enters (exists) in the guard zone, the optional external buzzer gives a loud alarm.
Type:OP03-21
Code no.:000-030-097
Name
1
Buzzer
2
Cable tie
3
Heat-shrink- tube
4
Double-sided Tape 9760
Attach the two-way cable and MJ-A7SPF0007-050C cable to the OPTION port at the rear of the
display unit. See the above figure.
1. Cut the NH connector at the end of the external buzzer cable to an acceptable length.
2. Solder the external buzzer cable to the MJ-A7SPF0007-050C cable as shown below. Before
you solder the cores, cut the heat-shrink-tube in half and set the tubes to the cores of the
cable. Solder the cores, then set the tubes on the soldered point.
MJ-A7SPF0007-050C
3. Fasten the buzzer with the double-sided tape or two self-tapping screws (3x15 or 3x20, local
supply).
4-4
MJ-A10SPFW0001+R *
(0.2 m)
OPTION
MJ-10P
*: This cable is not required to connect the remote display only.
Type
PKB42SWH2940 000-153-221-10
CV-70N
3x0.25 BLK
MJ-A7SPF0007-050C (5 m)
MJ-7P
MJ-10P
MJB24P
MJ-B24LPF0010-xxx+R (10/20/30 m)
(xxx: 100、 200 or 300)
Code No.
000-162-185-10
000-165-283-10
000-800-851-00
Red
Solder
Black
Cut other cables off, and wrap here with tape.
External buzzer
Remote Display
Qty
Comment
1
One NH connector attached
4
1
40 mm
1
25 mm x 25 mm
External buzzer

Advertisement

Table of Contents
loading

This manual is also suitable for:

193519451835

Table of Contents