4. OPTIONAL EQUIPMENT

4.3 Remote display

The FURUNO Display unit FMD-811, MODEL1832 or GD-280/380, etc. can be connected
to this radar as a remote display. To interconnect them, use a cable attached with or set as
option for the remote display. Also, the optional EMI core (Type: CP03-31001, Code
No.:008-556-830) should be attached to the remote display cable to prevent a noise.
1. Unscrew all connecter nuts at the rear of the display unit.
2. Unfasten all screws to remove the display cover.
3. Pass the signal cable from the OPTION port of the display unit cover to the hole as
shown in the figure below and then connect it to SPU board.
4. Fix the shield wire with a screw used to fixed the SPU board.
5. Attach the EMI core RFC-H13 on the signal cable.
EMI core
RFC-H13
Attach cable-tie approx. 90 mm from the end of
cable and attack EMI core.
Fix the EMI core steadily with cable-tie CV-100.
Remote display cable