PowerSeries - PC1616/PC1832/PC1864

Programmable Output Options

01
Residential Burglary and Fire Bell Output
02
For Future Use
03
Sensor Reset [*][7][2]
04
2-Wire Smoke Support (PGM 2 only)
05
System Armed Status
06
Ready To Arm
07
Keypad Buzzer Follow Mode
08
Courtesy Pulse
09
System Trouble Output (with Trouble options)
10
System Event (Strobe with Event options)
11
System Tamper (all sources)
12
TLM and Alarm
13
Kissoff Output
14
Ground Start Pulse
15
Remote Operation (DLS Support)
16
For Future Use
17
Away Armed Status
[009] PGM1 and PGM2 Output Programming (Main Panel)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564].
PC1616 and PC1832 have 2 on-board PGMs (PGM 1 and 2). PC1864 has 4 on-board PGMs (PGM 1-4).
Default
19
I____I____I
PGM 1
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564].
Default
01
I____I____I PGM 3 (main panel/PC5208)*
01
I____I____I PGM 4 (main panel/PC5208)*
01
I____I____I PGM 5 (PC5208)
01
I____I____I PGM 6 (PC5208)
These two sections above allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on the PC5208. If you
use both the main panel and the PC5208 outputs, PGM3 will work identically to the first PC5208 output, and PGM4 will work identically to the
second PC5208 output.
[011] PGM 11 to PGM 14 Output Programming (PC5204)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564].
Default
01
I____I____I PGM 11
01
I____I____I PGM 12
Other System Options

[012] Keypad Lockout Options

If Keypad Lockout is active, the panel cannot be disarmed with a key switch.
Default
000
Number of Invalid Codes Before Lockout (001-255 codes, 000 to disable)
I____I____I____I
000
Lockout Duration (000-255 minutes)
I____I____I____I
18
Stay Armed Status
19
Command Output #1 ([*][7][1])
20
Command Output #2 ([*][7][2])
21
Command Output #3 ([*][7][3])
22
Command Output #4 ([*][7][4])
23
24-hr Silent Input (PGM 2 only)
24
24-hr Audible Input (PGM 2 only)
25
Delayed Fire and Burglary Output
26
Battery Test Output
28
Holdup Output
29
Zone Follower Output (Zones 1-8)
30
Partition Status Alarm Memory
31
Alternate Communicator
32
For Future Use
33
For Future Use
34
Away Armed with no Zone Bypassed Status
35
Zone Follower Output (Zones 9-16)
Default
10
I____I____I
Default
01
01
01
01
Default
01
I____I____I PGM 13
01
I____I____I PGM 14
32
36
Zone Follower Output (Zones 17-24)
37
Zone Follower Output (Zones 25-32)
38
Zone Follower Output (Zones 33-40)
39
Zone Follower Output (Zones 41-48)
40
Zone Follower Output (Zones 49-56)
41
Zone Follower Output (Zones 57-64)
PGM 2
I____I____I PGM 7 (PC5208)
I____I____I PGM 8 (PC5208)
I____I____I PGM 9 (PC5208)
I____I____I PGM 10 (PC5208)
Output types [03], [04]
and [20] cannot be used
together on the same
system.