[013] First System Options

Opt
Def
ON
Normally Closed Loops
1
Double End-of-Line Resistors
2
Panel shows all Troubles when armed
3
Tampers/Faults do not show as open
4
Auto-Arm Schedule in [*][6] and installers
5
Audible Exit Fault Enabled
6
Event Buffer Follows Swinger Shutdown
7
Temporal Three Fire Signal Enabled
8

[014] Second System Options

Opt
Def
ON
Arm /Disarm Bell Squawk Enabled
1
Bell Squawk During Auto-Arm
2
Bell Squawk On Exit Delay
3
Bell Squawk On Entry Delay
4
Bell Squawk On Trouble
5
Audible Exit with Urgency
6
Exit Delay Termination Enabled
7
Residential Fire Bell is Continuous
8

[015] Third System Options

Opt
Def
ON
Fire Key Enabled
1
Panic Key Audible (Bell / Beeps)
2
Quick Exit Enabled
3
Quick Arming Enabled (No Code Required)
4
Code Required for Bypassing
5
Master Code NOT Changeable
6
TLM Enabled
7
TLM Audible (Bell) when Armed
8

[016] Fourth System Options

Opt
Def
ON
AC Trouble Displayed
1
Trouble Light Flashes if AC Fails
2
Blank Keypad when Not Used
3
Code required to remove Keypad Blanking
4
Keypad Backlighting is Enabled
5
Power Save Mode Enabled
6
Bypass Status Displayed While Armed
7
Keypad Tampers Enabled
8
OFF
End-of-Line Resistors
Single End-of-Line Resistors
Panel shows only Fire Troubles when armed
Tampers/Faults show as open
Auto-arm Schedule in Installer Programming Only
Audible Exit Fault Disabled
Event Buffer Logs Events past Shutdown
Standard Pulsed Fire Signal
OFF
Arm /Disarm Bell Squawk Disabled
No Bell Squawk During Auto-Arm
No Bell Squawk On Exit Delay
No Bell Squawk On Entry Delay
No Bell Squawk On Trouble
Silent Exit Delay
Exit Delay Termination Disabled
Residential Fire Bell is Cut-off
OFF
Fire Key Disabled
Panic Key Silent
Quick Exit Disabled
Quick Arming Disabled (Code Required)
Code Not Required for Bypassing
Master Code Changeable
TLM Disabled
TLM Trouble Beeps when Armed
OFF
AC Trouble Not Displayed
Trouble Light does NOT follow AC Status
Keypad Blanking Disabled
No Code Required
Keypad Backlighting is Disabled
Power Save Mode Disabled
Bypass Status Not Displayed While Armed
Keypad Tampers Disabled