PowerSeries - PC1616/PC1832/PC1864
PC1616/1832/1864 Wiring Diagram
1. Inser
1. Insert standoff into cabinet
mounting hole in the desired location.
mounting hole in the desired location.
Snap in place.
Snap
2. Position circuit board mounting holes
2. Position circuit board mounting holes
over standoffs. Press firmly on board
over standoffs. Press firmly on board
to snap in place.
to snap
220 - 240V
220 - 240V
, 50/60Hz, 200mA
, 50/60Hz, 200mA
AC
AC
IMPORTANT!
IMPORTANT!
Minimum 1/4" (6.4mm) separation
Minimum 1/4" (6.4mm) separation
must be maintained at all points between
must be maintained at all points between
BATTERY/AC WIRING and all other
BATTERY/AC WIRING and all other
wiring connections
wiring connections
AC in
AC in
(Neut)
(Neut)
PE
PE
AC in
AC in
FUSE
FUSE
(Line)
(Line)
Replace fuse only with same type (20mm) rated 250V/315mA
PC5003C Cabinet Shown
Use Model Power UC1 f or (2) Battery Installations
IMPORTANT:
IMPORTANT:
1.This equipment, Alarm Controller PC1616/1832/1864/etc.
1.This equipment, Alarm Controller PC1616/1832/1864/etc.
shall be installed and used within an environment that provides
shall be installed and used within an environment that provides
the pollution degree max 2 and overvoltages category II
the pollution degree max 2 and overvoltages category II
NON HAZARDOUS LOCATIONS, indoor only. The equipment is
NON HAZARDOUS LOCATIONS, indoor only. The equipment is
FIXED and PERMANENTLY CONNECTED and is designed to be
FIXED and PERMANENTLY CONNECTED and is designed to be
installed by service persons only; [service person is defined as a
installed by service persons only; [service person is defined as a
person having the appropriate technical training and experience
person having the appropriate technical training and experience
necessary to be aware of hazards to which that person may be
necessary to be aware of hazards to which that person may be
exposed in performing a task and of measures to minimize the risks
exposed in performing a task and of measures to minimize the risks
to that person or other persons.]
to that person or other persons.]
2.The connection to the mains supply must be made as per the local
2.The connection to the mains supply must be made as per the local
authorities rules and regulations: In the UK as per BS6701.
authorities rules and regulations: In the UK as per BS6701.
An appropriate disconnect device must be provided as part of the
An appropriate disconnect device must be provided as part of the
building installation. Where it is not possible to rely on identification of
building installation. Where it is not possible to rely on identification of
the NEUTRAL in the AC MAINS SUPPLY, the disconnecting device
the NEUTRAL in the AC MAINS SUPPLY, the disconnecting device
must disconnect both poles simultaneously (LINE and NEUTRAL).
must disconnect both poles simultaneously (LINE and NEUTRAL).
The device shall disconnect the supply during servicing.
The device shall disconnect the supply during servicing.
3.The equipment enclosure must be secured to the
3.The equipment enclosure must be secured to the building structure
before operation.
before operation.
4.The power supply must be fail-safe and an approved type, acceptable
to the local authorities.
5.Internal wiring must be routed in a manner that prevents:
nal wiring must be routed in a manner that prevents:
- Excessive strain on wire and on terminal connections;
- Excessive strain on wire and on terminal connections;
- Loosening of terminal; connections;
- Loosening of terminal; connections;
- Damage of conductor insulation
- Damage of conductor insulation
6.Disposal of the used batteries shall be made according to the waste
recovery and recycling regulations applicable to the intended market.
recovery and recycling regulations applicable to the intended market.
7. Two batteries may be used to provide the required backup time.
WARNING:
WARNING:
High Voltage. Disconnect AC Power
High Voltage. Disconnect AC Power
and telephone lines before servicing.
and telephone lines before servicing
PC Board
PC Board
Stand Off
Stand Off
Cabinet
Cabinet
Transformer
Transformer
(Neut)
(Neut)
To EGND on
To EGND on
Control Module
Control Module
Transformer
Transformer
(Line)
(Line)
WARNING:
WARNING:
Inspect wiring and ensure connections are correct before applying power.
Inspect wiring and ensure connections are correct before applying power.
Do NOT route any wiring over circuit boards. Maintain at least 1"(25.4mm) separation.
Do NOT route any wiring over circuit boards. Maintain at least 1"(25.4mm) separation.
building structure
BAT+BAT-
BAT+BAT-
Tye Wraps (not supplied) recommended
Tye Wraps (not supplied) recommended
No. 14 AWG or smaller conductor
No. 14 AWG or smaller conductor
CON1
CON1
BAT+BAT-
BAT+BAT-
AUX+
AUX+
BELL+
BELL+
AC AC
AC AC
RED BLK YEL GRN
RED BLK YEL GRN
AUX-
AUX-
BELL-
BELL-
16.5V
16.5V
/40VA
/40VA
AC
AC
FUSE
FUSE
Incorrect connections may result in PTC failure or improper operation.
PC1616/1832/1864
PC1616/1832/1864
AUX+ and Keybus (Red) are Internally Connected
are Internally
Total current draw from Keypads, PGM Outputs and
Total current draw from Keypads, PGM Outputs and
Aux circuits must not exceed 500mA.
Aux circuits must not exceed 500m
CON1
CON1
AC AC
+ AUX -
+ BELL - RED BLK YEL GRN
1 PGM 2 3 PGM 4
Keybus
2
UA503
UA503
PC1616/1832/1864
PC1616/1832/1864
PC-LINK
PC-LINK
Internally Connected
Internally Connected
PC1864
PC1864
PC1864
PC1864
Only
Only
PC1832
PC1832
Only
Only
PGM1
PGM1
PGM3
PGM3
Z1 COM Z2
Z1 COM Z2
Z3 COM Z4
Z3 COM Z4
Z5 COM Z6
Z5 COM Z6
Z7 COM Z8
Z7 COM Z8
EGND
EGND
PGM2
PGM2
PGM4
PGM4
NOTE:
CE, AS/N7S versions
use (1) 7AHr Battery Only
7 AHr
12VDC/ 7 Ah Battery
UA503
UA503
PC-LINK
PC-LINK
Internally Connected
Internally Connected
PC1864
PC1864
PC1864
PC1864
Only
Only
PC1832
PC1832
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 EGND RING TIP R-1 T-1
PGMs
Zones
DSC
DSC
TB-2
TB-2
RING
RING
R-1
R-1
TIP
TIP
T-1
T-1
DSC
DSC
Only
Only
TB-2
TB-2
Telephone

Hide quick links: