Seventh System Option Code; Keypad Zone Assignment; Eighth System Option Code; Ninth System Option Code - DSC PC1616 Installation Manual

Power series
Hide thumbs Also See for PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864

[019] Seventh System Option Code

Option
Description
[1]
For Future Use
[2]
For Future Use
[3]
ON: when disarming, the keypad will display only the first alarm to occur during the last arming period.
OFF: when disarming, the keypad will display all zones that were in alarm during the last arming period
[4]-[5]
For Future Use
[6]
ON: the green LED indicator on the keypads indicate the status of AC on the system
OFF: the green LED indicator on the keypads indicate the partition ready status
[7]
ON: all user access codes can enter the User Functions menu.
OFF: only the Master Code can enter the User Functions menu.
[8]
For Future Use

[020] Keypad Zone Assignment

Enter the two-digit zone number to be assigned to each keypad assigned to a specific slot. Only one keypad can be assigned to a specific slot. See
Keypad Assignment. Valid entries are from [00] to [64].

[021] Eighth System Option Code

Option
Description
[1]
ON: access codes will not be accepted by the system during entry delay.
OFF: an access code can be used to disarm the system during entry delay
[2]-[5]
For Future Use
[6]
ON: key-switches and wireless keys can only disarm the system during an entry delay
OFF: key-switches and wireless keys can disarm the system regardless if entry delay is active or not.
[7]-[8]
For Future Use

[022] Ninth System Option Code

Option
Description
[1]
ON: an access code is required for access to the [][1], [][2], [][3] menus.
OFF: no access code is required for [][1], [][2], [][3] menu access.
[2]-[3]
For Future Use
ON: only the Master code can be used to bypass a hold up zone.
[4]
OFF: any valid access code can bypass a hold up zone.
For Future Use
[5]
[6]
ON: RF Delinquency Enabled, if any wireless zone supervisory transmission is not received by the RF5132 during a 15-minute period,
the RF5132 will place the panel into Not Ready To Arm mode. In the armed state, the Zone faults will generate tamper alarms. The
panel will generate a silent trouble (NO trouble beeps but the Trouble LED is turned ON) called "RF Device Delinquency", which is
only viewable in [][2] (Trouble Menu). The user can override the condition and arm the panel by using the feature.
OFF: RF Delinquency Disabled, the system will not indicate an RF Delinquency when a zone supervisory transmission is not
received during a 15 minute period.
Future Use
[7]
[8]
ON: when the system is armed in Stay mode, during the Exit delay, the system will sound one beep every 3 seconds.
OFF: when the system is armed in Stay mode, the system will be silent during the Exit delay.
[023] Tenth System Option Code
Option
Description
[1]
ON: the keypad [F] emergency key will only beep three times to acknowledge that the button has been pressed. The system will not
activate the bell output. OFF: the system will activate the bell output and beep the keypad.
[2]
For Future Use
[3]
ON: the system will only transmit the Test Transmission reporting code if the system is armed at the time the system is programmed
to report the event. OFF: the system will always report the Test Transmission reporting code at the programmed time.
[4]
ON: the system changes the Test Transmission Reporting Cycle Time from Days to Hours.
OFF: the Test Transmission Reporting Cycle Time is in Days.