3.3.1 Programming Toggle Options

Enter the 3-digit programming section number:
• The Armed light turn OFF and
• The Ready light turns ON
• The keypad indicates the ON or OFF status of the toggle
option according to the chart
• To toggle an option ON or OFF, press the corresponding num-
ber on the keypad. The display changes accordingly
• When all the toggle options are configured correctly, press the [#] key to exit
• The Ready light turns OFF and the Armed light turns ON

3.3.2 Programming Decimal and Hexadecimal (HEX) Data

• Enter the 3-digit programming section number
• The Armed light turns OFF and the Ready light turns ON
• Enter the data written in the boxes
For sections that require multiple 2 or 3-digit numbers, the keypad beeps twice after each 2 or 3-digit entry then moves to the next item on
the list. After the last digit in the section is entered, the keypad beeps rapidly 5 times then exits the programming section. The Ready light
turns OFF and the Armed light turns ON.
For sections that do not require data for every box (such as phone numbers), press the [#] key to exit the programming section after entering
all the required data. The Ready light turns OFF and the Armed light turns ON.
The [#] key can be pressed at any time to exit a program section. All changes made up to that point are saved.
HEX (or hexadecimal) digits are sometimes required. To enter a HEX digit, press the
[
] key to begin HEX programming. The Ready light flashes.
Refer to the following chart and press the number corresponding to the HEX digit
required. The Ready light will continue to flash. Press [
decimal programming. The Ready light will turn ON.
In addition to the standard digits 0-9, HEX digits and special dialer functions can also be programmed.

3.3.3 Exiting Installer Programming

To exit installer programming, press the [#] key when the panel is waiting for a 3-digit section number (the Armed light is ON).

3.3.4 Viewing Programming

LED and LCD5501Z Keypads
Any programming section can be viewed from an LED or LCD5501Z key-
pad. When a programming section is entered, the keypad will immediately
display the first digit of information programmed in that section.
The keypad displays the information using a binary format, according to the
following chart:
Press any of the Emergency keys (Fire, Auxiliary or Panic) to advance to the
next digit.
When all the digits in a section have been viewed, the panel will exit the section. The Ready light will turn OFF, and the Armed light
will turn ON. The system is now waiting for the next 3-digit programming section number to be entered. Press the [#] key to exit the
section.
LCD Keypad
The keypad will immediately display all the information programmed when a programming section is entered. Use the arrow keys (< >) to scroll
through the data being displayed. Scroll past the end of the data displayed or press the [#] key to exit the section.
Keypad Type
LED
Fixed-Message LCD
Programmable-Message LCD # Displayed
] again to return to normal
10
Option ON
ON
Zone Light
ON
Indicator #
Value
Enter
Telephone Dialer
HEX [A]
Press [][1][]
Not Supported
HEX [B]
Press [][2][]
Simulated [] key
HEX [C]
Press [][3][]
Simulated [#] key
HEX [D]
Press [][4][]
Dial tone search
HEX [E]
Press [][5][]
Two second pause
HEX [F]
Press [][6][]
End of Number
Option OFF
OFF
Zone Light
OFF
Indicator #
Dash [-]
Displayed