Keypad Partition /Slot and Function Key Programming

[000] Keypad Enrollment

This must be done at each keypad requiring programming.
[0] Slot address (For the partition, 0-8; for the slot, 1-8). For example, to enroll a keypad in partition 3, slot 1, enter (31).
[1] Function Key 1 Assignment (Valid entries are 00-32)
[2] Function Key 2 Assignment (Valid entries are 00-32)
[3] Function Key 3 Assignment (Valid entries are 00-32)
[4] Function Key 4 Assignment (Valid entries are 00-32)
[5] Function Key 5 Assignment (Valid entries are 00-32)
Function Key Options
(enter these values below in the table immediately following):
00
Not used
01
Select Partition 1
02
Select Partition 2
03
Stay Arm
04
Away Arm
05
[
][9] No-Entry Arm
06
[
][4] Chime On / Off
07
[
][6][——][4] System Test
08
[
][1] Bypass Mode
09
[
][2] Trouble Display
10
[
][3] Alarm Memory
11
[
][5] Access Code Programming
Partition/Slot
ICON / LED Defaults
Full Message Defaults
KEYPAD 1
KEYPAD 2
KEYPAD 3
KEYPAD 4
KEYPAD 5
KEYPAD 6
KEYPAD 7
KEYPAD 8

[001]-[004] Zone Definitions

00
Null Zone (Not Used)
01
Delay 1*
02
Delay 2*
03
Instant*
04
Interior*
05
Interior, Stay/Away*
06
Delay, Stay/Away*
07
Delayed 24-hr Fire (Hardwired)**
08
Standard 24-hr Fire (Hardwired)
09
24-hr Supervisory
10
24-hr Supervisory Buzzer*
11
24-hr Burglary*
12
24-hr Holdup*
*For burglary applications only
12
[
][6] User Functions
13
Command Output #1 [
14
Command Output #2 [
15
Global Stay Arming
16
[
][0] Quick Exit
17
[
][1] Reactivate Stay/Away Zones
18
Global Away Arming
19
Command Output 3 [
20
For Future Use
21
Command Output 4 [
22
Global Disarming
23
Bypass Recall
[20] Zone
Assigned
11
00
18
00
00
00
00
00
00
00
00
00
(enter the values below in the table immediately following):
13
24-hr Gas*
14
24-hr Heating*
15
24-hr Auxiliary (Medical)*
16
24-hr Panic*
17
24-hr Emergency*
18
24-hr Sprinkler*
19
24-hr Water*
20
24-hr Freeze*
21
24-hr Latching Tamper*
22
Momentary Keyswitch Arm*
23
Maintained Keyswitch Arm*
24
For Future Use
25
Interior/Delay*
** For residential fire applications only
24
][7][1]
25
26
][7][2]/Sensor Reset
27
28
29
30
31
][7][3]
32
][7][4]
33
Key 1
Key 2
03
04
03
04
26
29
30
31
32
35
36
37
39
41
81
87
88
30
Recall Bypass Group
For Future Use
Time and Date
Select Partition 3
Select Partition 4
Select Partition 5
Select Partition 6
Select Partition 7
Select Partition 8
For Future Use
Key 3
Key 4
06
14
06
14
24-hr Non-alarm*
Auto-Verified Fire
Fire Supervisory
Day Zone*
Instant Stay/Away*
24-hr Bell/Buzzer
24-hr Non-Latching Tamper Zone
Night Zone
For Future Use
24-hr Carbon Monoxide (hardwired)
24-hr Wireless Carbon Monoxide
Delay 24-hr Fire (Wireless/Addressable)**
Standard 24-hr Fire (Wireless/Addressable)**
Key 5
16
16