Function Key Options - DSC PC1580BABT Installation Manual

For pc1580
Table of Contents

Advertisement

K
E
Y
described below. A function is activated by pressing and
holding the appropriate key for two seconds.
"Stay" – Stay Arm
Pressing this key will arm the system in the Stay mode,
meaning that all Stay/Away type zones will be automatically
bypassed. Delay type zones will provide entry and exit
delay. The Quick Arm feature must be enabled in order for
this key to function (programming section [10], option [6]).
"Away" – Away Arm
Pressing this key will arm the system in the Away mode. All
Stay/Away type zones and all other non-bypassed zones
will be active at the end of the exit delay. Delay type zones
will provide entry and exit delay. The Quick Arm feature must
be enabled in order for this key to function.
"Chime" – Door Chime On / Off
Pressing this key will toggle the Door Chime feature ON or
OFF. One solid beep means that the feature has been
disabled and three short beeps means that it has been
enabled (see Section 3.4 – "[ ] [4] Door Chime").
"Reset" – Reset Smoke Detectors
Pressing this key will cause the panel to activate for five
seconds all PGM outputs programmed as Sensor Reset.
"Exit" – Activate Quick Exit
Pressing this key will cause the panel to activate the Quick Exit
feature (See Section 3.4 – "[ ] [0] Quick Exit").

3.5.1 Function Key Options

The following is a list of Function Key options available.
Each option is listed according to their programming code,
followed by their corresponding [ ] key command. For more
information regarding each function, please refer to the
appropriate segment in section 3.4 ("[ ] Commands")
[00] – Null Key
The key is not used and will perform no function when
pressed.
[01]-[02]– Not Used
[03] – Stay Arm
Same as described in Function Keys – Section 3.5.
[04] – Away Arm
Same as described in Function Keys – Section 3.5.
[05] – [ ] [9] No-Entry Delay Arm
Once this function key is pressed the user must enter a valid
user code. The system will arm and remove the entry delay
from the system when the exit delay expires (see Section 3.4
– "[ ] [9] Arming Without Entry Delay").
P
A
D
V
C
O
[06] – [ ] [4] Door Chime On / Off
Same as described in Function Keys – Section 3.5.
[07] – [ ] [6] [----] [4] System Test
This function key provides the user with a simple method for
testing the system.
[08] – [ ] [1] Bypass Mode
This function key provides the user with a simple method for
entering the Bypass Mode. If a user code is required, it must
be entered before zone bypassing can be performed.
[09] – [ ] [2] Trouble Display
This function key provides the user with a simple method for
entering the Trouble Display Mode.
[10] – [ ] [3] Alarm Memory
This function key provides the user with a simple method for
entering the Alarm Memory Display Mode.
[11] – [ ] [5] Programming Access Codes
This function key provides the user with a simple method for
programming user codes. Once this key is pressed, a valid
master code must be entered before the panel will allow
programming to be performed.
[12] – [ ] [6] User Functions
This function key provides the user with a simple method for
programming user functions. Once this key is pressed, the
Master code must be entered before the panel will allow user
functions to be performed.
[13] – [ ] [7] [1] Utility Output
This function key provides the user with a simple method for
activating a PGM Output programmed as utility output (see
section 5.10 – "PGM outputs"). Once this key is pressed, a
valid user code must be entered.
[14] – [ ] [7] [2] Sensor Reset
Same as described in Function Keys – Section 3.5.
[15] – Not Used
[16] – [ ] [0] Quick Exit
Same as described in Function Keys – Section 3.5.
[17] – [ ] [1] Reactivate Stay/Away Zones
This function key provides the user with a simple method for
adding Stay/Away zones back into the system at night-time
(see Section 3.4 – "[ ] [1] Bypassing and Reactivating Stay/
Away Zones").