Transmit "No Read" Message

Parameter # 5Eh
Enable this option to transmit "NR" if a 1-D symbol does not decode, and "FR" if a 2-D
symbol does not decode. Any enabled prefix or suffixes are appended around this
message.
When the parameter is disabled, and a symbol can not be decoded, no message is sent to
the host.
Enable No Read
(01h)
*Disable No Read
(00h)