HEATING MODE (XP25 ONLY) — CLIMATE IQ™
This technology optimizes dehumidification settings for specific climates to
improve home comfort during cooling or heating operations.
Two climate settings are available:
Comfort ­ The system adjust compressor operation to increase air
temperature.
Normal ­ Standard system operation.
COOLING MODE — CLIMATE IQ™
Three climate settings are available:
Dry ­ The system supplies higher indoor airflow at all compressor
capacities, increasing efficiency by operating at a higher sensible to
total ratio.
Moderate ­ The system supplies indoor airflow that balances
efficiency and comfort.
Humid ­ The system supplies lower indoor airflow at all compressor
capacities, improving humidity removal by operating at a lower
sensible to total ratio.

Adjusting Humidification and Dehumidification Settings with

Non-Communicating Outdoor Units

HUMIDIFICATION SETTINGS — SYSTEM DEVICES SCREEN
Pre-adjustment REQUIREMENTS:
First the device has been installed.
Second, you pressed next at the "Add or Remove..." screen.
Configure the device as follows:
1.
In the "system devices" list, use the arrows to highlight System. Touch
edit.
2.
In the "System" list, use the arrows to highlight Humidification
Control Mode. Touch edit.
3.
Touch one of the radio buttons to select the mode of humidification
control; touch save. (After saving, check that the current value now
shows the new selection).
4.
Touch the back button to return to "Adjust a setting..." screen.
NOTE - If the defaults for the settings are shown in red, you are not required
to make any changes, but you must go into the edit tool, and touch save.
When all red text is gone, the back button will appear; touch it to return to the
"Adjust a setting..." screen.
How Humidification Mode Works
DISPLAY, BASIC AND PRECISION—These modes allow user con­
trol of relative humidity between 15 and 45%. These conditions must
be met for either mode to operate:
humidification mode has been enabled, and
the unit is in HEAT mode, and
humidification demand exists (24V present at H), and
DISPLAY mode indicates humidification is OFF.
BASIC mode mode also requires presence of heating demand
[Y for HP heat, or W for gas heat (W may be energized with G
de-energized)].
PRECISION—Outdoor temperature sensor is required.
Basic Dew Point Control adjustment mode will change the humidifica­
tion setpoint based on the outdoor temperature and a user-defined
dew point adjustment setting.
Precision Dew Point Control adjustment mode will operate when these
conditions are met:
humidification mode has been enabled, and
the unit is in HEAT mode, and
humidification demand exists (24V present at H).
®